Abstract
Microarc oxidation (MAO) has been regarded as one of the most effective technique to slow down the degradation rate of Mg and its alloys. In this work, MAO coating was successfully constructed on the surface of high-purity Zn for biomedical purpose. The microstructure, composition, corrosion resistance and biocompatibility of MAO-coated samples were investigated. It was found that micro/nano pores were homogenously distributed on the surface after MAO treatment in the electrolyte containing calcium and phosphorus components with pore size ranging from submicron scale to several micrometers. The MAO coating can modulate the corrosion rate of pure Zn substrate on the basis of chemical dissolution and galvanic corrosion between coating and substrate. MG63 cells cultured in the 100% extracts of MAO-coated sample exhibited significant cytotoxicity due to stimulated cell apoptosis induced by high concentration of released Zn2+, whereas excellent cytocompatibility was observed for 20% extracts. Meanwhile, cell adhesion was promoted on the porous structure generated during MAO process. The present research suggested that MAO treatment can be a promising approach on Zn and its alloys for bone implants.
Funding Information
  • Research Grants Council, University Grants Committee (5161101031)
  • National Natural Science Foundation of China (5161101031, 51871004, 51431002)
  • State Key Laboratory for Mechanical Behavior of Materials, Xi?an Jiaotong University (20182011)

This publication has 64 references indexed in Scilit: