Comparison of Boron‐Doped Diamond and Glassy Carbon Electrodes for Determination of Procaine Hydrochloride
- 15 January 2008
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 20 (2) , 137-143
Abstract
The electrochemical oxidation of procaine hydrochloride (PC⋅HCL, 2‐diethylaminoethyl 4‐aminobenzoate hydrochloride) was investigated at as‐deposited boron‐doped diamond (ad‐BDD) electrode, anodically oxidized BDD (ao‐BDD) electrode and glassy carbon (GC) electrode using cyclic voltammetry (CV). Well‐defined cyclic voltammograms were obtained for PC⋅HCL oxidation with high signal‐to‐background (S/B) ratio, low tendency for adsorption, good reproducibility and long‐term stability at ad‐BDD electrode, demonstrating its superior electrochemical behavior and significant advantages in contrast to ao‐BDD and GC electrode. At 100 μM PC⋅HCL, the voltammetric S/B ratio was nearly one order of magnitude higher at an ad‐BDD electrode than that at a GC electrode. In a separate set of experiments for oxidation of 100 μM PC⋅HCL, 96%, 92% and 84% of the initial oxidation peak current was retained at the ad‐BDD, ao‐BDD and GC electrode, respectively, by stirring the solution after the tenth cycle. The current response was linearly proportional to the square root of the scan rate within the range 10–1000 mV s−1 in 10 μM PC⋅HCL solutions, indicating that the oxidation process was diffusion‐controlled with negligible adsorption at an ad‐BDD surface. The good linearity was observed for a concentration range from 5 to 200 μM with a linear equation of y=0.03517x+0.65346 (r=0.999), and the detection limit was 0.5 μM for oxidation of PC⋅HCL at the ad‐BDD electrode. The ad‐BDD electrode could maintain 100% of its original activity after intermittent use for 3 months.Keywords
This publication has 38 references indexed in Scilit:
- Amperometric biosensor based on tyrosinase immobilized on a boron-doped diamond electrodeBiosensors and Bioelectronics, 2007
- Development of an amperometric biosensor based on covalent immobilization of tyrosinase on a boron-doped diamond electrodeElectrochemistry Communications, 2006
- Electrochemical Oxidation of Oxalic Acid at Highly Boron-Doped Diamond ElectrodesAnalytical Chemistry, 2006
- AC impedance studies of anodically treated polycrystalline and homoepitaxial boron-doped diamond electrodesElectrochimica Acta, 2003
- Electrochemical Glucose Detection Using Nickel-Implanted Boron-Doped Diamond ElectrodesElectrochemical and Solid-State Letters, 2002
- Metal-Modified Diamond Electrode as an Electrochemical Detector for GlucoseChemistry Letters, 2001
- Selective Electrochemical Detection of Dopamine in the Presence of Ascorbic Acid at Anodized Diamond Thin Film ElectrodesElectrochemical and Solid-State Letters, 1999
- Enhanced Signal-to-Background Ratios in Voltammetric Measurements Made at Diamond Thin-Film Electrochemical InterfacesAnalytical Chemistry, 1996
- Local anesthetics measured by lipophilic β-cyclodextrin-based ion-selective electrodesElectroanalysis, 1996
- Electrochemical and Surface Structural Characterization of Hydrogen Plasma Treated Glassy Carbon ElectrodesLangmuir, 1996