Influence of different kinematics on shaping ability and accumulated hard tissue debris: an ex vivo study
- 25 November 2024
- journal article
- research article
- Published by Springer Nature in Odontology
- Vol. 113 (3) , 973-983
Abstract
To determine the shaping ability, the amount of accumulated hard tissue debris (AHTD) and untouched area is generated by different kinematics through micro-CT. Thirty-two mesial roots of mandibular molars with Vertucci type IV were pre-scanned through micro-CT evaluation and randomized to one of the four experimental groups according to the kinematics tested: Continuous Rotation (CR), Reciprocation (REC), Optimum Torque Reverse (OTR) and Jeni motion. The root canal preparation was performed with HyFlex EDM (Coltène/Whaledent AG) up to OneFile. After each file used, irrigation was performed with 2 mL 5.25% NaOCl for 1 min. The final rinse was performed with 1 ml of 5.25% NaOCl followed by a 1 ml of 17% EDTA and, 1 ml of distilled water. Then, the samples were scanned and the images, before and after preparation, were superimposed and analyzed to determine the AHTD, untouched areas, canal transportation, centering ability, and shaping time. Data were statistically analyzed using Kruskal–Wallis test and Dunn post hoc with p < 0.05. No significant differences were detected among the tested kinematics in terms of untouched areas, AHTD, canal transportation and shaping time (p > 0.05). Significantly more untouched areas were detected in the coronal third compared to the middle (p = 0.0301) and apical ones (p = 0.0399) under continuous rotation. Moreover, a significantly higher centering ratio in the middle third compared to the apical was observed for Jeni motion (p = 0.0207). The tested kinematics showed similar untouched areas, AHTD, shaping ability and shaping time. All motions determined an appropriate mechanical preparation; yet, none of them was able to prepare all canal walls and keep the root canals completely free from hard tissue debris.Keywords
This publication has 39 references indexed in Scilit:
- Correlative Bacteriologic and Micro–Computed Tomographic Analysis of Mandibular Molar Mesial Canals Prepared by Self-Adjusting File, Reciproc, and Twisted File SystemsJournal of Endodontics, 2013
- Micro–computed Tomography Study of Oval-shaped Canals Prepared with the Self-adjusting File, Reciproc, WaveOne, and ProTaper Universal SystemsJournal of Endodontics, 2013
- Microtomography-based Comparison of Reciprocating Single-File F2 ProTaper Technique versus Rotary Full SequenceJournal of Endodontics, 2011
- Shaping Ability of Reciprocating Motion in Curved Root Canals: A Comparative Study with Micro–Computed TomographyJournal of Endodontics, 2011
- Accumulated hard tissue debris levels in mesial roots of mandibular molars after sequential irrigation stepsInternational Endodontic Journal, 2010
- The Quality of Root Canal Preparation and Root Canal Obturation in Canals Treated with Rotary versus Self-adjusting Files: A Three-dimensional Micro-computed Tomographic StudyJournal of Endodontics, 2010
- Current Challenges and Concepts in the Preparation of Root Canal Systems: A ReviewJournal of Endodontics, 2004
- Leakage Along Apical Root Fillings in Curved Root Canals. Part I: Effects of Apical Transportation on Seal of Root FillingsJournal of Endodontics, 2000
- Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomographyJournal of Endodontics, 1996
- A comparison of canal preparations in straight and curved root canalsOral Surgery, Oral Medicine, Oral Pathology, 1971