Simultaneous speciation of arsenic (As(III), MMA, DMA, and As(V)) and selenium (Se(IV), Se(VI), and SeCN−) in petroleum refinery aqueous streams
- 22 May 2010
- journal article
- review article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 397 (5) , 1755-1761
Abstract
High-performance liquid chromatography (HPLC) coupled to an ICP-MS with an octapole reaction system (ORS) has been used to carry out quantitative speciation of selenium (Se) and arsenic (As) in the stream waters of a refining process. The argon dimers interfering with the 78Se and 80Se isotopes were suppressed by pressurizing the octapole chamber with 3.1 mL min−1 H2 and 0.5 mL min−1 He. Four arsenic species arsenite—As(III), arsenate (As(V)), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA)—and three inorganic Se species—selenite Se(IV), selenate Se(VI), and selenocyanate (SeCN−)—were separated in a single run by ion chromatography (IC) using gradient elution with 100 mmol L−1 NH4NO3, pH 8.5, adjusted by addition of NH3, as eluent. Repeatabilities of peak position and of peak area evaluation were better than 1% and about 3%, respectively. Detection limits (as 3σ of the baseline noise) were 81, 56, and 75 ng L−1 for Se(IV), Se(VI), and SeCN−, respectively, and 22, 19, 25, and 16 ng L−1 for As(III), As(V), MMA, and DMA, respectively. Calibration curve R 2 values ranged between 0.996 and 0.999 for the arsenic and selenium species. Column recovery for ion chromatography was calculated to be 97 ± 6% for combined arsenic species and 98 ± 3% for combined selenium species. Because certified reference materials for As and Se speciation studies are still not commercially available, in order to check accuracy and precision the method was applied to certified reference materials, BCR 714, BCR 1714, and BCR 715 and to two different refinery samples—inlet and outlet wastewater. The method was successfully used to study the quantitative speciation of selenium and arsenic in petroleum refinery wastewaters.Keywords
This publication has 21 references indexed in Scilit:
- Speciation analysis of arsenic and selenium compounds in environmental and biological samples by ion chromatography–inductively coupled plasma dynamic reaction cell mass spectrometerAnalytica Chimica Acta, 2007
- Arsenic Speciation Analysis in Water Samples: A Review of The Hyphenated TechniquesEnvironmental Monitoring and Assessment, 2005
- Peer Reviewed: Arsenic Speciation2004
- Determination of arsenic in petroleum refinery streams by electrothermal atomic absorption spectrometry after multivariate optimization based on Doehlert designSpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Determination of selenite, selenate and selenocyanate in waters by ion chromatography-hydride generation-atomic fluorescence spectrometry (IC-HG-AFS)Journal of Analytical Atomic Spectrometry, 2001
- Selenium speciation in pretreated human urine by ion-exchange chromatography and ICP-MS detectionJournal of Analytical Atomic Spectrometry, 2001
- The application of inductively coupled plasma dynamic reaction cell mass spectrometry for measurement of selenium isotopes, isotope ratios and chromatographic detection of selenoamino acidsJournal of Analytical Atomic Spectrometry, 2000
- Speciation of organic selenium compounds by reversed-phase liquid chromatography and inductively coupled plasma mass spectrometry. Part II. Sector field instrument with high mass resolutionJournal of Analytical Atomic Spectrometry, 2000
- Organic and inorganic selenium speciation in urine by on-line vesicle mediated high-performance liquid chromotography–focused microwave digestion–hydride generation–inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1998
- Speciation of inorganic selenium and selenoaminoacids by on-line reversed-phase high-performance liquid chromatography–focused microwave digestion–hydride generation-atomic detectionJournal of Analytical Atomic Spectrometry, 1996