Technical Feasibility of Isolated Bowman Layer Graft Preparation by Femtosecond Laser: A Pilot Study
Authors:
- 26 May 2017
- journal article
- research article
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 27 (6) , 675-677
Abstract
Purpose: To evaluate the technical feasibility of isolated Bowman layer (BL) graft preparation by femtosecond laser (FSL) and to compare the ultrastructural morphology to manually dissected grafts. Methods: Five whole globes were placed in custom-made eye holders and debrided of epithelium. After programming a dissection depth of 20 μm, the FSL was docked into position and 5 isolated BL grafts were created. From 5 additional globes, corneoscleral buttons were procured, mounted in artificial anterior chambers, and stripped of BL via the previously described manual technique. Three specimens from both series were randomly selected and assigned to transmission electron microscopy for ultrastructural evaluation and thickness measurements. Results: All dissections were uneventful and 10 total grafts were produced: 5 by FSL and 5 by manual dissection. Mean graft thickness was 37 (±8.6) μm (n = 3) for the FSL group and 11.7 (±1.6) μm (n = 3) for the manually dissected group. Transmission electron microscopy revealed a thick but relatively smooth posterior cut edge in the FSL group, versus a virtually isolated BL with irregular rests of dispersed stroma in the manually dissected group. Conclusions: Femtosecond laser may have potential for harvesting intact BL and with a smooth posterior surface, but accompanied by variable amounts of anterior stroma owing to technical limitations.Keywords
This publication has 12 references indexed in Scilit:
- Donor Tissue Preparation for Bowman Layer TransplantationCornea, 2016
- Corneal Densitometry and Higher Order Aberrations After Bowman Layer TransplantationCornea, 2016
- Bowman Layer Transplantation to Reduce and Stabilize Progressive, Advanced KeratoconusOphthalmology, 2015
- Femtosecond Laser Cutting of Multiple Thin Corneal Stromal Lamellae for Endothelial BioengineeringCornea, 2015
- Femtosecond Laser Cutting of Endothelial GraftsCornea, 2015
- Midstromal Isolated Bowman Layer Graft for Reduction of Advanced KeratoconusJAMA Ophthalmology, 2014
- Accuracy and Reproducibility of Cap Thickness in Small Incision Lenticule ExtractionJournal of Refractive Surgery, 2013
- Repeatability of laser in situ keratomileusis flap thickness measurement by Fourier-domain optical coherence tomographyJournal of Cataract & Refractive Surgery, 2011
- Isolated Bowman layer transplantation to manage persistent subepithelial haze after excimer laser surface ablationJournal of Cataract & Refractive Surgery, 2010
- Flap dimensions created with the IntraLase FS laserJournal of Cataract & Refractive Surgery, 2004