Abstract
Symmetrical and unsymmetrical faults pose significant challenges to the operation of microgrids with integrated renewable energy sources. Unbalanced faults lead to deviations in point of common coupling (PCC) voltage and introduce negative sequence voltage components, driving the system away from its stable operating region. This article proposes a unified voltage ride-through (VRT) scheme for a dual voltage source inverter-fed microgrid system to ride through unsymmetrical voltage sags and swells by regulating the PCC voltage while simultaneously minimizing the negative sequence voltage and oscillations in the injected active power with dual sequence current injection. Moreover, VRT is achieved by maintaining the PCC voltages within the nominal range through an appropriate generation of reference voltage. In addition to voltage regulation, frequency deviations due to power imbalances during fault conditions are also damped by adjusting real power supplied to the system. Thereby, consolidated control of positive and negative sequence voltage, oscillating power components, phase voltage deviations, and frequency variations at the PCC is achieved through the proposed VRT scheme, ensuring power quality and reliable operation within rated current limits. The developed control scheme is validated through simulation and experimental studies on the developed hardware prototype for various voltage scenarios.
Funding Information
  • Ministry of Science and Technology, DST India, (SR/FST/ET-II/2021/891)

This publication has 32 references indexed in Scilit: