Image-derived input function in PET brain studies
- 1 September 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 33 (9) , 982-989
Abstract
Background Image-derived input function (IDIF) from carotid arteries is an elegant alternative to full arterial blood sampling for brain PET studies. However, a recent study using blood-free IDIFs found that this method is particularly vulnerable to patient motion. The present study used both simulated and clinical [11C](R)-rolipram data to assess the robustness of a blood-based IDIF method (a method that is ultimately normalized with blood samples) with regard to motion artifacts. Methods The impact of motion on the accuracy of IDIF was first assessed with an analytical simulation of a high-resolution research tomograph using a numerical phantom of the human brain, equipped with internal carotids. Different degrees of translational (from 1 to 20 mm) and rotational (from 1 to 15°) motions were tested. The impact of motion was then tested on the high-resolution research tomograph dynamic scans of three healthy volunteers, reconstructed with and without an online motion correction system. IDIFs and Logan-distribution volume (VT) values derived from simulated and clinical scans with motion were compared with those obtained from the scans with motion correction. Results In the phantom scans, the difference in the area under the curve (AUC) for the carotid time–activity curves was up to 19% for rotations and up to 66% for translations compared with the motionless simulation. However, for the final IDIFs, which were fitted to blood samples, the AUC difference was 11% for rotations and 8% for translations. Logan-VT errors were always less than 10%, except for the maximum translation of 20 mm, in which the error was 18%. Errors in the clinical scans without motion correction appeared to be minor, with differences in AUC and Logan-VT always less than 10% compared with scans with motion correction. Conclusion When a blood-based IDIF method is used for neurological PET studies, the motion of the patient affects IDIF estimation and kinetic modeling only minimally.Keywords
This publication has 18 references indexed in Scilit:
- Image-Derived Input Function for Brain PET Studies: Many Challenges and Few OpportunitiesJournal of Cerebral Blood Flow & Metabolism, 2011
- Partial volume corrected image derived input functions for dynamic PET brain studies: Methodology and validation for [11C]flumazenilNeuroImage, 2008
- An input function estimation method for FDG-PET human brain studiesNuclear Medicine and Biology, 2007
- PET imaging of the dopamine transporter with 18F-FECNT: a polar radiometabolite confounds brain radioligand measurements.2006
- Quantification method in [18F]fluorodeoxyglucose brain positron emission tomography using independent component analysisNuclear Medicine Communications, 2005
- Quantification of brain phosphodiesterase 4 in rat with (R)-[11C]Rolipram-PETNeuroImage, 2005
- Image-Derived Input Function for [11C]Flumazenil Kinetic Analysis in Human BrainMolecular Imaging and Biology, 2003
- Non-invasive assessment of skeletal kinetics using fluorine-18 fluoride positron emission tomography: evaluation of image and population-derived arterial input functionsEuropean Journal of Nuclear Medicine and Molecular Imaging, 1999
- Noninvasive Quantification of the Cerebral Metabolic Rate for Glucose Using Positron Emission Tomography, 18F-Fluoro-2-Deoxyglucose, the Patlak Method, and an Image-Derived Input FunctionJournal of Cerebral Blood Flow & Metabolism, 1998
- Computerized three‐dimensional segmented human anatomyMedical Physics, 1994