Development, optimization, and use of an APCI source with temperature-controlled vaporization of solid and liquid samples
- 23 November 2012
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (4) , 1373-1381
Abstract
A trend is observed in mass spectrometry, in which solid samples without prior dissolution and chromatographic separation are brought directly into the ion source and are ionized, e.g., by corona discharge (Atmospheric Solids Analysis Probe) or plasma (Direct Analysis in Real Time). The Direct Inlet Probe-atmospheric-pressure chemical ionization (APCI) ion source presented here, which was coupled to a high-resolution quadrupole time-of-flight–mass spectrometer, differs from most of the other ion sources in having temperature-programmed heating of the sample. The resulting possibility to reduce ion suppression and ion-molecule reactions in the ion source was shown by the separation of two fatty acid methyl esters as a result of their boiling point difference. Using caffeine as sample, certain source parameters such as the auxiliary gas flow, the drying gas flow, and the position of the probe tip in the ion source were optimized. The ability to perform quantitative analyses was shown by the linear concentration response (R 2 = 0.9984) observed when analyzing different caffeine concentrations. An extract of a Chinese medicinal herb was used to examine the reproducibility (relative standard deviations of the most abundant m/z signals were ≤8.1 %). It was also possible to distinguish milled samples of Radix Angelicae sinensis and Radix Angelicae gigas from each other and to identify the coumarins they contain without sample preparation. Supplying synthetic air instead of nitrogen to the ion source makes APCI in the negative mode possible as well; this was proven by the analysis of n-nonyl-β-d-maltoside.Keywords
This publication has 19 references indexed in Scilit:
- Rapid Detection and Identification of Impurities in Ten 2-Naphthalenamines Using an Atmospheric Pressure Solids Analysis Probe in Conjunction with Ion Mobility Mass SpectrometryEuropean Journal of Mass Spectrometry, 2011
- Application of the Mason−Schamp Equation and Ion Mobility Mass Spectrometry To Identify Structurally Related Compounds in Crude OilAnalytical Chemistry, 2010
- Molecular Ions and Protonated Molecules Observed in the Atmospheric Solids Analysis Probe Analysis of SteroidsEuropean Journal of Mass Spectrometry, 2010
- Combination Atmospheric Pressure Solids Analysis Probe and Desorption Electrospray Ionization Mass Spectrometry Ion SourceAnalytical Chemistry, 2009
- Quantitation of Chemical Warfare Agents Using the Direct Analysis in Real Time (DART) TechniqueAnalytical Chemistry, 2009
- Control of Strobilurin Fungicides in Wheat Using Direct Analysis in Real Time Accurate Time-of-Flight and Desorption Electrospray Ionization Linear Ion Trap Mass SpectrometryAnalytical Chemistry, 2008
- Analysis of the Inhibition of the Ergosterol Pathway in Fungi Using the Atmospheric Solids Analysis Probe (ASAP) MethodJournal of the American Society for Mass Spectrometry, 2007
- Analysis of Solids, Liquids, and Biological Tissues Using Solids Probe Introduction at Atmospheric Pressure on Commercial LC/MS InstrumentsAnalytical Chemistry, 2005
- Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient ConditionsAnalytical Chemistry, 2005
- Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray IonizationScience, 2004