Study of X-ray radiation damage in the AGIPD sensor for the European XFEL
Authors:
Preprint
Abstract
The European X-ray Free Electron Laser (XFEL), currently being constructed in Hamburg and planning to be operational in 2017 for users, will deliver 27,000 fully coherent, high brilliance X-ray pulses per second with duration less than 100 fs. The unique features of the X-ray beam pose major challenges for detectors used at the European XFEL for imaging experiments, in particular a radiation tolerance of silicon sensors for doses up to 1 GGy for 3 years of operation at an operating voltage above 500 V. One of the detectors under development at the European XFEL is the Adaptive Gain Integrating Pixel Detector (AGIPD), which is a hybrid detector system with ASICs bump-bonded to p+n silicon pixel sensors. We have designed the silicon sensors for the AGIPD, which have been fabricated by SINTEF and delivered in the beginning of February of 2013. To demonstrate the performance of the AGIPD sensor with regard to radiation hardness, mini-sensors with the same pixel and guard-ring designs as the AGIPD together with test structures have been irradiated at the beamline P11 of PETRA III with 8 keV and 12 keV monoenergetic X-rays to dose values up to 10 MGy. The radiation hardness of the AGIPD sensor has been proven and all electrical properties are within specification before and after irradiation. In addition, the oxide-charge density and surface-current density from test structures have been characterized as function of the X-ray dose and compared to previous measurements for test structures produced by four vendors.Keywords
All Related Versions
- Version 1, 2013-12-13, ArXiv
- Published version: Journal of Instrumentation, 9 (5), C05022.
This publication has 14 references indexed in Scilit:
- Design of the AGIPD sensor for the European XFELJournal of Instrumentation, 2013
- Investigation of X-ray induced radiation damage at the Si-SiO2interface of silicon sensors for the European XFELJournal of Instrumentation, 2012
- The AGIPD detector for the European XFELJournal of Instrumentation, 2012
- Optimization of the radiation hardness of silicon pixel sensors for high x-ray doses using TCAD simulationsJournal of Instrumentation, 2012
- Study of X-ray radiation damage in silicon sensorsJournal of Instrumentation, 2011
- The adaptive gain integrating pixel detector AGIPD a detector for the European XFELNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Single mimivirus particles intercepted and imaged with an X-ray laserNature, 2011
- Simulation and experimental study of plasma effects in planar silicon sensorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Impact of plasma effects on the performance of silicon sensors at an X-ray FELNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Requirements for and development of 2 dimensional X-ray detectors for the European X-ray Free Electron Laser in HamburgJournal of Instrumentation, 2009