Geometric distortion of panoramic reconstruction in third molar tilting assessments: a comprehensive evaluation
Authors:
- 1 October 2018
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 47 (7) , 20170467
Abstract
Objectives:To evaluate the geometric distortion of tilting of mandibular third molars with respect to second molars on panoramic reconstruction.Material and methods:Cone-beam computed tomography (CBCT) reconstructions of 160 third molars, obtained due to an indication of risk of inferior alveolar nerve damage during surgery, were used. CBCT-reconstructed panoramic images were used as bi-dimensional images, to avoid distortions other than geometric distortions. The angle between the second and the third molar was measured in bi- and three-dimensional images. Student’s t-test was used to assess the null-hypothesis of no difference between bi- and three-dimensional measurements.Results:A significant mean difference (−2.3°± 6.3°) between bi- and three-dimensional measurements was found, with an absolute error of 3.6°± 5.7° and a relative error of 10%. These findings comprehensively explain the geometric distortion on panoramic radiographs.Conclusion:Although a widely used and undoubtedly useful tool for diagn...Keywords
This publication has 26 references indexed in Scilit:
- Radiographic Evaluation of Regenerated Bone Following Poly(Lactic-Co-Glycolic) Acid/Hydroxyapatite and Deproteinized Bovine Bone Graft in Sinus LiftingJournal of Craniofacial Surgery, 2013
- Mandibular traumatic peripheral osteoma: a case reportOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2011
- Accuracy of angular measurements and assessment of distortion in the mandibular third molar region on panoramic radiographsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2011
- New dimensions in endodontic imaging: part 1. Conventional and alternative radiographic systemsInternational Endodontic Journal, 2009
- The Prophylactic Extraction of Third Molars: A Public Health HazardAmerican Journal of Public Health, 2007
- Accuracy of three-dimensional measurements using cone-beam CTDentomaxillofacial Radiology, 2006
- Clinical evaluation of the effects of radiographic distortion on the position and classification of mandibular third molarsDentomaxillofacial Radiology, 2005
- Geometric accuracy of the NewTom 9000 Cone Beam CTDentomaxillofacial Radiology, 2005
- Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)Dentomaxillofacial Radiology, 2004
- Computerized tomography in the management and follow‐up of extensive periapical lesionDental Traumatology, 1999