Pulse contour cardiac output derived from non‐invasive arterial pressure in cardiovascular disease
- 21 September 2010
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 65 (11) , 1119-1125
Abstract
Summary: Pulse contour methods determine cardiac output semi‐invasively using standard arterial access. This study assessed whether cardiac output can be determined non‐invasively by replacing the intra‐arterial pressure input with a non‐invasive finger arterial pressure input in two methods, Nexfin CO‐trek ® and Modelflow ® , in 25 awake patients after coronary artery bypass surgery. Pulmonary artery thermodilution cardiac output served as a reference. In the supine position, the mean (SD) differences between thermodilution cardiac output and Nexfin CO‐trek were 0.22 (0.77) and 0.44 (0.81) l.min −1 , for intra‐arterial and non‐invasive pressures, respectively. For Modelflow, these differences were 0.70 (1.08) and 1.80 (1.59) l.min −1 , respectively. Similarly, in the sitting position, differences between thermodilution cardiac output and Nexfin CO‐trek were 0.16 (0.78) and 0.34 (0.83), for intra‐arterial and non‐invasive arterial pressure, respectively. For Modelflow, these differences were 0.58 (1.11) and 1.52 (1.54) l.min −1 , respectively. Thus, Nexfin CO‐trek readings were not different from thermodilution cardiac output, for both invasive and non‐invasive inputs. However, Modelflow readings differed greatly from thermodilution when using non‐invasive arterial pressure input.Keywords
This publication has 29 references indexed in Scilit:
- Validation of brachial artery pressure reconstruction from finger arterial pressureJournal Of Hypertension, 2008
- The arterial WindkesselMedical & Biological Engineering & Computing, 2008
- Non‐invasive pulsatile arterial pressure and stroke volume changes from the human fingerExperimental Physiology, 2005
- Reconstruction of brachial pressure from finger arterial pressure during orthostasisJournal Of Hypertension, 2004
- Continuous Cardiac Output in Septic Shock by Simulating a Model of the Aortic Input ImpedanceAnesthesiology, 1999
- An adequate strategy for the thermodilution technique in patients during mechanical ventilationIntensive Care Medicine, 1990
- Improvement of cardiac output estimation by the thermodilution method during mechanical ventilationIntensive Care Medicine, 1986
- Effects of peripheral vasoconstriction on the measurement of blood pressure in a fingerCardiovascular Research, 1985
- Direct Blood Pressure Measurement —Dynamic Response RequirementsAnesthesiology, 1981
- An artificial arterial system for pumping hearts.Journal of Applied Physiology, 1971