Abstract
Semi‐continuous column fractionation of canola oil deodorizer distillate using supercritical CO2 (SCCO2) was carried out to determine the feasibility of value‐added processing of this feed material for the recovery of bioactive components such as sterols and tocopherols and to determine the effect of operating conditions [pressure (20, 25 MPa using a temperature gradient of 70–100 °C), temperature (70, 100 °C) and a linear temperature gradient (70–100 °C at 25 MPa)] on extract yield and separation efficiency. Total extract yield increased significantly (p ≤ 0.05) with pressure, whereas at isobaric conditions (25 MPa) the highest yield was obtained at the lowest temperature tested (70 °C). Fractionation efficiency was reflected in the composition of fractions and was affected by operating conditions. Residue composition was determined by extract yield in addition to selectivity. Use of the thermal gradient (70–100 °C) decreased the content of volatiles, free fatty acids and tocopherols while increasing sterol content significantly (p ≤ 0.05) to a level of 40% (GC area %) in the residue obtained at 25 MPa. The findings indicate the potential of canola oil deodorizer distillate as a source of sterols and warrant further research on the countercurrent column fractionation to improve the separation efficiency.
Funding Information
  • Natural Sciences and Engineering Research Council of Canada
  • Alberta Agricultural Research Institute
  • Alberta Crop Industry Development Fund

This publication has 14 references indexed in Scilit: