Modular MR-compatible lower leg exercise device for whole-body scanners
- 27 January 2011
- journal article
- technical report
- Published by Springer Nature in Skeletal Radiology
- Vol. 40 (10) , 1349-1354
Abstract
Purpose To develop a modular MR-compatible lower leg exercise device for muscle testing using a clinical 3 T MR scanner. Materials and methods An exercise device to provide isotonic resistance to plantar- or dorsiflexion was constructed from nonferrous materials and designed for easy setup and use in a clinical environment. Validation tests were performed during dynamic MR acquisitions. For this purpose, the device was tested on the posterior lower leg musculature of five subjects during 3 min of exercise at 30% of maximum voluntary plantarflexion during 31-phosphorus MR spectroscopy (31P-MRS). Measures of muscle phosphocreatine (PCr), inorganic phosphate (Pi), and pH were obtained before, during, and after the exercise protocol. Results At the end of exercise regimen, muscle PCr showed a 28% decrease from resting levels (to 21.8 ± 3.9 from 30.4 ± 3.0 mM) and the average PCr recovery rate was 35.3 ± 8.3 s. Muscle Pi concentrations increased 123% (to 14.6 ± 4.7 from 6.5 ± 3.3 mM) and pH decreased 1.5% (to 7.06 ± 0.14 from 7.17 ± 0.07) from resting levels. Conclusion The described MR-compatible lower leg exercise was an effective tool for data acquisition during dynamic MR acquisitions of the calf muscles. The modular design allows for adaptation to other whole-body MR scanners and incorporation of custom-built mechanical or electronic interfaces and can be used for any MR protocol requiring dynamic evaluation of calf muscles.Keywords
This publication has 17 references indexed in Scilit:
- Mitochondrial Function and Insulin Resistance in Overweight and Normal-Weight ChildrenThe Journal of Clinical Endocrinology & Metabolism, 2009
- An MR‐compatible bicycle ergometer for in‐magnet whole‐body human exercise testingMagnetic Resonance in Medicine, 2009
- Phosphocreatine recovery kinetics following low- and high-intensity exercise in human triceps surae and rat posterior hindlimb musclesAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2009
- Calf muscle perfusion at peak exercise in peripheral arterial disease: Measurement by first‐pass contrast‐enhanced magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2007
- Eddy‐current induction in extended metallic parts as a source of considerable torsional momentJournal of Magnetic Resonance Imaging, 2006
- Dynamic interleaved 1H/31P STEAM MRS at 3 Tesla using a pneumatic force-controlled plantar flexion exercise rigMagnetic Resonance Materials in Physics, Biology and Medicine, 2005
- Relaxation times of 31P‐metabolites in human calf muscle at 3 TMagnetic Resonance in Medicine, 2003
- Two‐pedal ergometer for in vivo MRS studies of human calf musclesMagnetic Resonance in Medicine, 2001
- A simple calf muscle ergometer for use in a standard whole‐body mr scannerMagnetic Resonance in Medicine, 1990
- Data on the distribution of fibre types in thirty-six human musclesJournal of the Neurological Sciences, 1973