Patient-specific instruments in total knee arthroplasty
- 7 January 2014
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (2) , 259-265
Abstract
In recent years, patient-specific instruments (PSI) has been introduced with the aim of reducing the overall costs of the implants, minimising the size and number of instruments required, and also reducing surgery time. The purpose of this study was to perform a review of the current literature, as well as to report about our personal experience, to assess reliability of patient specific instrument system in total knee arthroplasty (TKA). A literature review was conducted of PSI system reviewing articles related to coronal alignment, clinical knee and function scores, cost, patient satisfaction and complications. Studies have reported incidences of coronal alignment ≥3° from neutral in TKAs performed with patient-specific cutting guides ranging from 6 % to 31 %. PSI seem not to be able to result in the same degree of accuracy as the CAS system, while comparing well with standard manual technique with respect to component positioning and overall lower axis, in particular in the sagittal plane. In cases in which custom-made cutting jigs were used, we recommend performing an accurate control of the alignment before and after any cuts and in any further step of the procedure, in order to avoid possible outliers.Keywords
This publication has 31 references indexed in Scilit:
- The radiological outcomes of patient‐specific instrumentation versus conventional total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2013
- Preliminary experience with the patient-specific templating total knee arthroplastyActa Orthopaedica, 2012
- Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 KneesThe Journal of Arthroplasty, 2012
- Are Patient-specific Cutting Blocks Cost-effective for Total Knee Arthroplasty?Clinical Orthopaedics and Related Research, 2012
- A prospective study comparing the functional outcome of computer-assisted and conventional total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2012
- Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKAClinical Orthopaedics and Related Research, 2012
- Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional techniqueInternational Orthopaedics, 2008
- Custom-Fit Total Knee Arthroplasty (OtisKnee) Results in MalalignmentThe Journal of Arthroplasty, 2008
- Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty SurgeryThe Journal of Arthroplasty, 2007
- Randomized Control Trial Comparing Radiographic Total Knee Arthroplasty Implant Placement Using Computer Navigation Versus Conventional TechniqueThe Journal of Arthroplasty, 2005