Electrospun quantum dots/polymer composite porous fibers for turn-on fluorescent detection of lactate dehydrogenase
Authors:
- 25 July 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry
- Vol. 22 (35) , 18471-18478
Abstract
A novel enzyme sensor based on CdSe quantum dots (QDs)/polycaprolactone (PCL) composite porous fibers has been prepared via a simple electrospinning method. We choose PCL, a biocompatible polymer, as the host polymer for the electrospun fibers and prepare CdSe QDs as sensing probes. Experiments demonstrate that the CdSe QDs are miscible and chemically inert to PCL in the electrospinning solvent mixture containing N,N-dimethylformamide and chloroform. Therefore, the CdSe QDs are uniformly distributed within the PCL fibers, leading to good preservation of their original fluorescence properties. In addition, secondary porous structures of the fibers are produced by introducing a porogen to accelerate inner-fiber analyte diffusion and increase the sensitivity of this sensor. These prepared fluorescent fibers can be reversibly quenched by nicotinamide adenine dinucleotide (NAD) due to the electron transfer (ET) process between NAD and the CdSe QDs. Based on the films formed by these fibers and an enzyme-catalyzed reaction for converting NAD to its reduced form NADH, this sensor has successfully realized the fluorescence turn-on detection of an NAD-dependent enzyme, lactate dehydrogenase (LDH). The detection time is only 10 min per sample, and linear calibration plots of the activity of LDH are obtained from 200–2400 U L−1. These QD composite porous fibers can be developed as a facile, rapid, sensitive and stable NAD-dependent enzyme detection platform and may find more applications in novel optical devices.Keywords
This publication has 42 references indexed in Scilit:
- Optical detection of choline and acetylcholine based on H2O2-sensitive quantum dotsBiosensors and Bioelectronics, 2011
- Monitoring Enzyme Activity Using a Diamagnetic Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast AgentJournal of the American Chemical Society, 2011
- Luminescent Kinase Activity Biosensors Based on a Versatile Bimolecular SwitchJournal of the American Chemical Society, 2011
- Molecular Beacon Based Bioassay for Highly Sensitive and Selective Detection of Nicotinamide Adenine Dinucleotide and the Activity of Alanine AminotransferaseAnalytical Chemistry, 2011
- β-Sitosterol Inhibits Cell Growth and Induces Apoptosis in SGC-7901 Human Stomach Cancer CellsJournal of Agricultural and Food Chemistry, 2009
- Enzymes and related proteins as cancer biomarkers: A proteomic approachClinica Chimica Acta, 2007
- Identification by Mass Spectrometry of a Hemoglobin Variant with an Elongated β-Globin ChainClinical Chemistry, 2005
- Sol–gel encapsulation of lactate dehydrogenase for optical sensing of ?-lactateBiosensors and Bioelectronics, 2002
- Development of a screen-printed amperometric biosensor for the determination of l-lactate dehydrogenase levelBiosensors and Bioelectronics, 2002
- Introduction of a (Poly)histidine Tag in -Lactate Dehydrogenase Produces a Mixture of Active and Inactive MoleculesAnalytical Biochemistry, 2001