Accuracy of computer-aided chest X-ray in community-based tuberculosis screening: Lessons from the 2016 Kenya National Tuberculosis Prevalence Survey
Open Access
- 23 November 2022
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 2 (11) , e0001272
Abstract
Community-based screening for tuberculosis (TB) could improve detection but is resource intensive. We set out to evaluate the accuracy of computer-aided TB screening using digital chest X-ray (CXR) to determine if this approach met target product profiles (TPP) for community-based screening. CXR images from participants in the 2016 Kenya National TB Prevalence Survey were evaluated using CAD4TBv6 (Delft Imaging), giving a probabilistic score for pulmonary TB ranging from 0 (low probability) to 99 (high probability). We constructed a Bayesian latent class model to estimate the accuracy of CAD4TBv6 screening compared to bacteriologically-confirmed TB across CAD4TBv6 threshold cut-offs, incorporating data on Clinical Officer CXR interpretation, participant demographics (age, sex, TB symptoms, previous TB history), and sputum results. We compared model-estimated sensitivity and specificity of CAD4TBv6 to optimum and minimum TPPs. Of 63,050 prevalence survey participants, 61,848 (98%) had analysable CXR images, and 8,966 (14.5%) underwent sputum bacteriological testing; 298 had bacteriologically-confirmed pulmonary TB. Median CAD4TBv6 scores for participants with bacteriologically-confirmed TB were significantly higher (72, IQR: 58–82.75) compared to participants with bacteriologically-negative sputum results (49, IQR: 44–57, p<0.0001). CAD4TBv6 met the optimum TPP; with the threshold set to achieve a mean sensitivity of 95% (optimum TPP), specificity was 83.3%, (95% credible interval [CrI]: 83.0%—83.7%, CAD4TBv6 threshold: 55). There was considerable variation in accuracy by participant characteristics, with older individuals and those with previous TB having lowest specificity. CAD4TBv6 met the optimal TPP for TB community screening. To optimise screening accuracy and efficiency of confirmatory sputum testing, we recommend that an adaptive approach to threshold setting is adopted based on participant characteristics.Keywords
Funding Information
- National Institute for Health Research (16/136/35)
- Wellcome (200901/Z/16/Z)
- Malawi Liverpool Wellcome Trust Programme (206545/Z/17/Z)
This publication has 24 references indexed in Scilit:
- A systematic review of the diagnostic accuracy of artificial intelligence-based computer programs to analyze chest x-rays for pulmonary tuberculosisPLOS ONE, 2019
- Kenya tuberculosis prevalence survey 2016: Challenges and opportunities of ending TB in KenyaPLOS ONE, 2018
- The long and winding road of chest radiography for tuberculosis detectionEuropean Respiratory Journal, 2017
- Automated chest-radiography as a triage for Xpert testing in resource-constrained settings: a prospective study of diagnostic accuracy and costsScientific Reports, 2015
- Diagnostic Accuracy of Computer-Aided Detection of Pulmonary Tuberculosis in Chest Radiographs: A Validation Study from Sub-Saharan AfricaPLOS ONE, 2014
- The Sensitivity and Specificity of Using a Computer Aided Diagnosis Program for Automatically Scoring Chest X-Rays of Presumptive TB Patients Compared with Xpert MTB/RIF in Lusaka ZambiaPLOS ONE, 2014
- O tórax e o envelhecimento: manifestações radiológicasJornal Brasileiro de Pneumologia, 2012
- The role and performance of chest X-ray for the diagnosis of tuberculosis: A cost-effectiveness analysis in Nairobi, KenyaBMC Infectious Diseases, 2005
- Active case finding of tuberculosis: historical perspective and future prospects.2005
- Variation of Chest Radiographic Patterns in Pulmonary Tuberculosis by Degree of Human Immunodeficiency Virus‐Related ImmunosuppressionClinical Infectious Diseases, 1997