Initial Performance Characterization of a Clinical Noise–Suppressing Reconstruction Algorithm for MDCT
Authors:
- 1 December 2011
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 197 (6) , 1404-1409
Abstract
OBJECTIVE. The number of CT examinations is increasing relatively dramatically, hence the radiation dose of the associated population. Thus, there is a need for efficient reconstruction methods with dose reduction potential that also maintain the image quality. In this article, we present the initial performance evaluation of such a reconstruction algorithm (iDose, Philips Healthcare). MATERIALS AND METHODS. iDose is a hybrid iterative reconstruction algorithm that provides enhanced image quality while reducing the radiation dose compared with the current clinical standard reconstruction. To quantify the advantages of this algorithm in image quality and dose reduction, we compared iDose with the conventional filtered back projection algorithm. Furthermore, we describe the performance of iDose with respect to several image quality metrics. RESULTS. The HU values remain stable while employing iDose. With iDose, the noise is significantly reduced. This is reflected by an improvement in the contrast-to-noise ...Keywords
This publication has 23 references indexed in Scilit:
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Radiation Dose-Reduction Strategies for Neuroradiology CT ProtocolsAmerican Journal of Neuroradiology, 2007
- Energy imparted‐based estimates of the effect of overscanning on adult and pediatric patient effective doses from multi‐slice computed tomographyMedical Physics, 2007
- The effect of overscanning on patient effective dose from multidetector helical computed tomography examinationsMedical Physics, 2005
- Priorities in optimisation of medical X-ray imaging—a contribution to the debateRadiation Protection Dosimetry, 2005
- Reduction of eye lens radiation dose by orbital bismuth shielding in pediatric patients undergoing CT of the head: A Monte Carlo studyMedical Physics, 2005
- Diagnostic CT Scans: Assessment of Patient, Physician, and Radiologist Awareness of Radiation Dose and Possible RisksRadiology, 2004
- Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CTBritish Journal of Radiology, 2003
- A dose reduction x-ray beam positioning system for high-speed multislice CT scannersMedical Physics, 2000
- Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurementsMedical Physics, 1999