Surrogate Distributed Radiological Sources—Part I: Point-Source Array Design Methods
- 9 January 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (2) , 213-223
Abstract
In this first part of a multi-paper series, we demonstrate a method for using arrays of point sources to emulate continuous distributed gamma-ray sources when measured from a standoff of at least several meters. The method relies on the Poisson deviance statistic to test whether the array source “looks like” its continuous analogue when measured by a particular gamma-ray detector moving through 3D space on a particular trajectory. This point-source method offers significant advantages over truly distributed sources such as powders, solutions, or aerosols; notably, arrays of sealed point sources are safer to both personnel and the environment, and are more easily deployed, reconfigured, ground-truthed, and removed. We use this Poisson deviance metric to design eight different mock distributed sources, ranging in complexity from a 36×36 m uniform square grid of 5 mCi Cu-64 sources to a configuration where regions of higher and zero activity are superimposed on a uniform baseline. We then present several example calculations for various detector systems, altitudes, array source spacings, and source patterns, and examine under what parameters it is possible to design a surrogate array source that is nearly indistinguishable from a truly continuous distributed source. In Part II, we will detail the design, manufacture, and testing of Cu-64 sealed sources at the Washington State University research reactor, discuss their deployment during the aerial measurement campaign, and present results from several measurements.Keywords
Funding Information
- Defense Threat Reduction Agency (HDTRA 13081-36239)
- Lawrence Berkeley National Laboratory with the U.S. Department of Energy (DE-AC02-05CH11231)
This publication has 21 references indexed in Scilit:
- Free-moving Quantitative Gamma-ray ImagingScientific Reports, 2021
- Contamination Measurements from Simultaneous Activated Potassium Bromide Radiological Dispersal Devices with a Collimated Vehicular SensorHealth Physics, 2021
- Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources With a Sparse Parametric AlgorithmIEEE Transactions on Nuclear Science, 2020
- Robotic Dispersal Technique for 35 GBq of 140La in an L-polygon PatternHealth Physics, 2019
- Gamma-Ray Point-Source Localization and Sparse Image Reconstruction Using Poisson LikelihoodIEEE Transactions on Nuclear Science, 2019
- A Methodology for Determining the Concentration of Naturally Occurring Radioactive Materials in an Urban EnvironmentNuclear Technology, 2018
- Recent developments in Geant4Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Overview of the Full-scale Radiological Dispersal Device Field TrialsHealth Physics, 2016
- Geant4 developments and applicationsIEEE Transactions on Nuclear Science, 2006
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003