Assay of Jorpes‐Mutt Secretin and Cholecystokinin

Authors:

Abstract
: The technique worked out in the senior author's laboratory for assaying secretin and cholecystokinin in cats and dogs has been described in detail. Highly purified samples of these hormones, supplied by the Swedish workers, were found to have a strength of 3,300 Ivy dog units of secretin and 22 Ivy dog units of cholecystokinin per mg, respectively. Due attention was paid to the extreme lability of the purified secretion.

This publication has 7 references indexed in Scilit: