Fully automatic three‐dimensional quantitative analysis of intracoronary optical coherence tomography
Authors:
- 11 June 2009
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 74 (7) , 1058-1065
Abstract
Objectives and background: Quantitative analysis of intracoronary optical coherence tomography (OCT) image data (QOCT) is currently performed by a time‐consuming manual contour tracing process in individual OCT images acquired during a pullback procedure (frame‐based method). To get an efficient quantitative analysis process, we developed a fully automatic three‐dimensional (3D) lumen contour detection method and evaluated the results against those derived by expert human observers. Methods: The method was developed using Matlab (The Mathworks, Natick, MA). It incorporates a graphical user interface for contour display and, in the selected cases where this might be necessary, editing. OCT image data of 20 randomly selected patients, acquired with a commercially available system (Lightlab imaging, Westford, MA), were pulled from our OCT database for validation. Results: A total of 4,137 OCT images were analyzed. There was no statistically significant difference in mean lumen areas between the two methods (5.03 ± 2.16 vs. 5.02 ± 2.21 mm2; P = 0.6, human vs. automated). Regression analysis showed a good correlation with an r value of 0.99. The method requires an average 2–5 sec calculation time per OCT image. In 3% of the detected contours an observer correction was necessary. Conclusion: Fully automatic lumen contour detection in OCT images is feasible with only a select few contours showing an artifact (3%) that can be easily corrected. This QOCT method may be a valuable tool for future coronary imaging studies incorporating OCT.Keywords
This publication has 13 references indexed in Scilit:
- Optical coherence tomography: High resolution intravascular imaging to evaluate vascular healing after coronary stentingCatheterization and Cardiovascular Interventions, 2008
- A novel approach for quantitative analysis of intracoronary optical coherence tomography: High inter‐observer agreement with computer‐assisted contour detectionCatheterization and Cardiovascular Interventions, 2008
- A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trialThe Lancet, 2008
- Does optical coherence tomography identify arterial healing after stenting? An in vivo comparison with histology, in a rabbit carotid modelHeart, 2008
- Evaluation by Optical Coherence Tomography of Neointimal Coverage of Sirolimus-Eluting Stent Three Months After ImplantationThe American Journal of Cardiology, 2007
- Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomographyEuropean Heart Journal, 2006
- Optical coherence tomographyCardiovascular Radiation Medicine, 2003
- American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (ivus)31When citing this document, the American College of Cardiology would appreciate the following citation format: Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, Pinto FJ, Rosenfield K, Siegel RJ, Tuzcu EM, Yock PG. ACC Clinical Expert Consensus Document on Standards for the acquisition, measurement and reporting of intravascular ultrasound studies: a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents (Committee to Develop a Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies [IVUS]). J Am Coll Cardiol2001;37:1478–92.33Address for reprints: This document is available on the ACC Website at www.acc.org. Reprints of this document are available for $5.00 each by calling 800-253-4636 (U.S. only) or writing to the Resource Center, American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, MD 20814-1699.JACC, 2001
- Experimental validation of geometric and densitometric coronary measurements on the new generation cardiovascular angiography analysis system (caas ii)Catheterization and Cardiovascular Diagnosis, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986