Scanning luminescence X‐ray microscopy: Imaging fluorescence dyes at suboptical resolution
- 1 November 1993
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 172 (2) , 121-129
Abstract
Summary: Scanning luminescence X‐ray microscopy is based on the use of the very small focused probe of a scanning X‐ray microscope to stimulate visible light emission from phosphors and dyes. Using an undulator X‐ray source and a Fresnel zone plate to produce a focused X‐ray probe, images of P31 phosphor grains with a resolution of 50–75 nm have been obtained, and luminescence from polystyrene spheres loaded with 50–100 μmol/g of fluorescent dye has been imaged. The resolution was not limited by the focused X‐ray probe (the microscope has imaged features at 36‐nm spacing in transmission mode) but by dark noise and the low net efficiency of the luminescence detection system used for this investigation. This technique may make it possible to image dye‐tagged sites of biochemical activity at the resolution of the X‐ray microscope in wet, unsectioned, and unfixed cells, especially with soft X‐ray optimized dyes. Because the image is formed from the detection of signal against a dark background, calculations suggest that the radiation dose for luminescence imaging of dye‐tagged features should be 2–22 times lower than it is in transmission X‐ray microscopy. A possible extension of the technique for three‐dimensional imaging at the transverse resolution of the X‐ray microscope is described, where visible light collection optics might be used to obtain submicrometre axial resolution.Keywords
This publication has 21 references indexed in Scilit:
- Measurements of wet metaphase chromosomes in the scanning transmission X‐ray microscopeJournal of Microscopy, 1993
- Absolute photoluminescent efficiency and photon damage of sodium salicylate in the soft-x-ray regimeJournal of the Optical Society of America B, 1992
- Diffraction-limited imaging in a scanning transmission x-ray microscopeOptics Communications, 1991
- The point‐spread function of a confocal microscope: its measurement and use in deconvolution of 3‐D dataJournal of Microscopy, 1991
- Coherent radiation for x-ray imaging—The soft x-ray undulator and the X1A beamline at the NSLSJournal of X-Ray Science and Technology, 1990
- Wavelength choice for soft x-ray laser holography of biological samplesApplied Optics, 1989
- A positron-sensitive photon detector for the UV or X-ray rangeNuclear Instruments and Methods, 1980
- Transmission microscopy of unmodified biological materials. Comparative radiation dosages with electrons and ultrasoft X-ray photonsUltramicroscopy, 1976
- Fluorescent Products from Irradiated Amino Acids and ProteinsRadiation Research, 1975
- Spiegelsysteme streifenden Einfalls als abbildende Optiken für RöntgenstrahlenAnnalen der Physik, 1952