Patient-Specific Modeling of Corneal Refractive Surgery Outcomes and Inverse Estimation of Elastic Property Changes
- 22 December 2010
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 133 (1) , 011002
Abstract
The purpose of this study is to develop a 3D patient-specific finite element model (FEM) of the cornea and sclera to compare predicted and in vivo refractive outcomes and to estimate the corneal elastic property changes associated with each procedure. Both eyes of a patient who underwent laser-assisted in situ keratomileusis (LASIK) for myopic astigmatism were modeled. Pre- and postoperative Scheimpflug anterior and posterior corneal elevation maps were imported into a 3D corneo-scleral FEM with an unrestrained limbus. Preoperative corneal hyperelastic properties were chosen to account for meridional anisotropy. Inverse FEM was used to determine the undeformed corneal state that produced error in anterior elevation between simulated and in vivo preoperative geometries. Case-specific 3D aspheric ablation profiles were simulated, and corneal topography and spherical aberration were compared at clinical intraocular pressure. The magnitude of elastic weakening of the residual corneal bed required to maximize the agreement with clinical axial power was calculated and compared with the changes in ocular response analyzer (ORA) measurements. The models produced curvature maps and spherical aberrations equivalent to in vivo measurements. For the preoperative property values used in this study, predicted elastic weakening with LASIK was as high as 55% for a radially uniform model of residual corneal weakening and 65% at the point of maximum ablation in a spatially varying model of weakening. Reductions in ORA variables were also observed. A patient-specific FEM of corneal refractive surgery is presented, which allows the estimation of surgically induced changes in corneal elastic properties. Significant elastic weakening after LASIK was required to replicate clinical topographic outcomes in this two-eye pilot study.
Keywords
This publication has 39 references indexed in Scilit:
- Differences in the early biomechanical effects of hyperopic and myopic laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2010
- Anterior Chamber Angle Opening during Corneoscleral Indentation: The Mechanism of Whole Eye Globe Deformation and the Importance of the LimbusInvestigative Ophthalmology & Visual Science, 2009
- Biomechanical Effects of Intraocular Pressure Elevation on Optic Nerve/Lamina Cribrosa before and after Peripapillary Scleral Collagen Cross-LinkingInvestigative Ophthalmology & Visual Science, 2009
- Three-Dimensional Modeling and Computational Analysis of the Human Cornea Considering Distributed Collagen Fibril OrientationsJournal of Biomechanical Engineering, 2008
- Full-field deformation of bovine cornea under constrained inflation conditionsBiomaterials, 2008
- Corneal hysteresis using the Reichert ocular response analyser: findings pre‐ and post‐LASIK and LASEKActa Ophthalmologica, 2008
- Optically inspired biomechanical model of the human eyeballJournal of Biomedical Optics, 2008
- Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyesJournal of Cataract & Refractive Surgery, 2007
- Biomechanics and wound healing in the corneaExperimental Eye Research, 2006
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005