Electronic Algorithmic Prediction of Central Vascular Catheter Use
Authors:
- Bala HotaBHBala Hota
- Susan C. BleasdaleSBSusan C. Bleasdale
- William TrickWTWilliam Trick
- Centers For Disease Control And Prevention EpicentersCECenters For Disease Control And Prevention Epicenters
- 2 January 2010
- journal article
- research article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 31 (1) , 4-11
Abstract
Objective.To develop prediction algorithms for the presence of a central vascular catheter in hospitalized patients with use of data present in an electronic health record. Such algorithms could be used for measurement of device utilization rates and for clinical decision support rules.Design.Criterion standard.Setting.John H. Stroger, Jr, Hospital of Cook County, a 464-bed public hospital in Chicago, Illinois.Participants.Patients admitted to the medical intensive care unit from May 31, 2005 through June 26, 2006 (derivation data set, May 31, 2005-September 28, 2005; validation data set, September 29, 2005-June 28, 2006).Methods.Covariates were collected from the electronic medical record for each patient; the outcome variable was presence of a central vascular device. Multivariate models were developed using the derivation set and the generalized estimating equation. Three models, each with increasing database requirements, were validated using the validation set. Device utilization ratios and performance characteristics were calculated.Results.Although Charlson score and duration of intensive care unit stay were significant predictors in all models, factors that indicated use or presence of a central line were also important. Device utilization rates derived from the algorithmic models were as accurate as those obtained using manual sampling.Conclusions.Automated calculation of central vascular catheter use is both feasible and accurate, providing estimates statistically similar to those obtained using manual surveillance. Prediction modeling of central vascular catheter use may enable automated surveillance of bloodstream infections and enhance important prevention interventions, such as timely removal of unnecessary central lines.Keywords
This publication has 20 references indexed in Scilit:
- Strategies to Prevent Central Line–Associated Bloodstream Infections in Acute Care HospitalsInfection Control & Hospital Epidemiology, 2008
- Effectiveness of Chlorhexidine Bathing to Reduce Catheter-Associated Bloodstream Infections in Medical Intensive Care Unit PatientsArchives of internal medicine (1960), 2007
- Sampling for Collection of Central Line–Day Denominators in Surveillance of Healthcare-Associated Bloodstream InfectionsInfection Control & Hospital Epidemiology, 2006
- Preliminary Assessment of an Automated Surveillance System for Infection ControlInfection Control & Hospital Epidemiology, 2004
- Administrative Databases Provide Inaccurate Data for Surveillance of Long-Term Central Venous Catheter-Associated InfectionsInfection Control & Hospital Epidemiology, 2003
- Automatic Electronic Laboratory-Based Reporting of Notifiable Infectious DiseasesEmerging Infectious Diseases, 2002
- The Impact of Hospital-Acquired Bloodstream InfectionsEmerging Infectious Diseases, 2001
- Use of an Estimation Method to Derive an Appropriate Denominator to Calculate Central Venous Catheter-Associated Bloodstream Infection RatesInfection Control & Hospital Epidemiology, 1998
- Improving Hospital-Acquired Infection Rates: The CDC ExperienceThe Joint Commission Journal on Quality Improvement, 1996
- Nosocomial Infection Rates for Interhospital Comparison: Limitations and Possible SolutionsInfection Control & Hospital Epidemiology, 1991