Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens
Authors:
Open Access
- 1 September 2023
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (9) , 16
Abstract
Purpose: To identify risk factors of ocular anterior segment measurement error by the IOLMaster 700 in eyes implanted with an implantable Collamer lens (ICL). Methods: In total, 152 patients with clear lens (152 eyes, group 1) and another 32 cataract patients (57 eyes, group 2) who underwent ICL implantation were included, and the presence of measurement error by the IOLMaster 700 was determined based on B-scan images. The risk factors for measurement error were evaluated by logistic regression, and the optimal threshold was determined using receiver operating characteristic analysis. Results: The ICL was misidentified as the anterior surface of the crystalline lens in 51.97% of eyes (79/152) in group 1 and 80.70% of eyes (46/57) in group 2. For every 100-µm decrease in the vault height, a 3.57- and 5.78-fold increase in the risk of measurement error was observed in group 1 and group 2, respectively. We identified an optimal threshold of the vault height at 389.47 µm for predicting biometric measurement error in eyes implanted with ICL, which showed an area under the curve of 0.93 (95% confidence interval, 0.90–0.97), a sensitivity of 0.87, and a specificity of 0.86. Conclusions: Patients with ICL implantation, particularly those with a vault height less than 389.47 µm, are at a greater risk of anterior segment biometric measurement error by the IOLMaster 700. Translational Relevance: The threshold of vault height can help to identify high-risk patients and further optimize biometric measurement.Keywords
This publication has 34 references indexed in Scilit:
- Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens ImplantationsYonsei Medical Journal, 2013
- Correlation between Preoperative Biometry and Posterior Chamber Phakic Visian Implantable Collamer Lens VaultingOphthalmology, 2012
- Central vault after phakic intraocular lens implantation: Correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient ageJournal of Cataract & Refractive Surgery, 2012
- Evaluation of Axial Length Measurement of the Eye Using Partial Coherence Interferometry and Ultrasound in Cases of Macular DiseaseOphthalmology, 2010
- Long-term Changes in Posterior Chamber Phakic Intraocular Collamer Lens Vaulting in Myopic PatientsOphthalmology, 2010
- Magnetic resonance imaging of the anteroposterior position and thickness of the aging, accommodating, phakic, and pseudophakic ciliary muscleJournal of Cataract & Refractive Surgery, 2010
- Metaanalysis of cataract development after phakic intraocular lens surgeryJournal of Cataract & Refractive Surgery, 2008
- Age-related changes in optical and biometric characteristics of emmetropic eyesJournal of Vision, 2008
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2008
- Effect of accommodation and pupil size on the movement of a posterior chamber lens in the phakic eyeOphthalmology, 2004