Difficult airway management practice changes after introduction of the GlideScope videolaryngoscope
- 19 March 2020
- journal article
- research article
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 37 (6) , 443-450
Abstract
BACKGROUND: Introduction of the GlideScope videolaryngoscope caused a change in use of other devices for difficult airway management. OBJECTIVE: The influence of the GlideScope videolaryngoscope on changes in the indications for and the frequency of use of flexible fibreoptic-assisted intubation and other difficult airway management techniques. DESIGN: Retrospective cohort study. SETTING: Tertiary care referral centre. METHODS: Two periods of equal length (647 days each) before and after introducing the GlideScope were compared. Information about patients who were intubated using nondirect laryngoscopic techniques were analysed. Data were retrieved from the anaesthesia and hospital information management systems. RESULTS: Difficult airway management techniques were used in 235/8306 (2.8%) patients before and in 480/8517 (5.6%) (P < 0.0001) patients after the introduction of the GlideScope. There was an overall 44.4% reduction in use of flexible fibreoptic bronchoscopy after GlideScope introduction [before 149/8306 (1.8%); after 85/8517 (1.0%), P < 0.0001]. The GlideScope replaced flexible fibreoptic bronchoscopy in most cases with expected and unexpected difficult intubation. In patients with limited mouth opening, flexible fibreoptic bronchoscopy was still mostly the first choice after the introduction of the GlideScope. There was a 70% reduction in the use of other difficult intubation techniques after the introduction of the GlideScope [before 84/8306 (1.0%); after 22/8517 (0.3%), P < 0.0001)]. CONCLUSION: The GlideScope videolaryngoscope replaced flexible fibreoptic bronchoscopy for most patients with expected and unexpected difficult intubation. In the case of limited mouth opening, flexible fibreoptic bronchoscopy was still the first choice after the introduction of the GlideScope. The reduced use of flexible fibreoptic bronchoscopy raises concerns that residents may not be adequately trained in this essential airway management technique. GlideScope use was disproportionately greater than the reduction in the use of flexible fibreoptic bronchoscopy and other difficult intubation techniques. This may be attributed to resident teaching and use in patients with low-to-moderate suspicion of difficult intubation.Keywords
This publication has 31 references indexed in Scilit:
- Association between the availability of videolaryngoscopes and the incidence of emergency surgical airway in the perioperative setting of a large academic medical centre: a retrospective observational studyBritish Journal of Anaesthesia, 2016
- Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adultsBritish Journal of Anaesthesia, 2015
- Obstetric Anaesthetists' Association and Difficult Airway Society guidelines for the management of difficult and failed tracheal intubation in obstetricsAnaesthesia, 2015
- A survey of Canadian anesthesiologists’ preferences in difficult intubation and “cannot intubate, cannot ventilate” situationsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2014
- The Impact of Video Laryngoscopy Use During Urgent Endotracheal Intubation in the Critically IllAnesthesia & Analgesia, 2013
- A Comparison of the C-MAC Video Laryngoscope to the Macintosh Direct Laryngoscope for Intubation in the Emergency DepartmentAnnals of Emergency Medicine, 2012
- Comparative Effectiveness of the C-MAC Video Laryngoscope versus Direct Laryngoscopy in the Setting of the Predicted Difficult AirwayAnesthesiology, 2012
- Routine Clinical Practice Effectiveness of the Glidescope in Difficult Airway ManagementAnesthesiology, 2011
- Difficult Airway Society guidelines for management of the unanticipated difficult intubationAnaesthesia, 2004
- Practice Guidelines for Management of the Difficult AirwayAnesthesiology, 2003