Evaluating Cochlear Implant Stimulation Strategies Through Wide-field Calcium Imaging of the Auditory Cortex
Preprint
Abstract
Cochlear Implants (CI) are an effective neuroprosthesis for humans with profound hearing loss, enabling deaf adults to have phone calls without lipreading and babies to have successful language development. However, CIs have significant limitations in complex hearing situations, motivating the need for further research, including studies in animal models. Here, we demonstrate the usefulness of wide field Ca++ imaging in assessing different CI stimulation strategies. One major challenge in electrophysiology in CI animals lies in excluding the CI electric artifacts from the recording, since they are orders of magnitude larger than the amplitude of action potentials. Also, electrophysiology can rarely sample large areas of neuropil at high spatial resolution. To circumvent these problems, we have set up an imaging system allowing us to monitor neural activity in the auditory cortex (AC) of CI supplied rats using the Ca++ sensitive dye OGB. Here we describe an initial experiment with this setup, in which we recorded cortical responses to 4 different stimulation patterns which were delivered across 3 CI channels to the contralateral ear. We then investigated two parameters that have been shown to affect intelligibility in CI users: pulse rate and relative pulse timing across CI channels. While pulse rate had only a very modest effect on the discriminability of the neural responses, the stimulation mode had a major effect, with simultaneous pulse timing, perhaps surprisingly, allowing much better pattern discrimination than interleaved sampling. The result suggests that allowing collisions of pulses on neighboring channels may not always be detrimental, at least if partial overlaps of pulses, in which anodic and cathodic pulse phases might cancel, are avoided.Keywords
This publication has 34 references indexed in Scilit:
- General anesthesia selectively disrupts astrocyte calcium signaling in the awake mouse cortexProceedings of the National Academy of Sciences, 2012
- Imaging Calcium in NeuronsNeuron, 2012
- Cortical activity patterns predict robust speech discrimination ability in noiseEuropean Journal of Neuroscience, 2011
- Spatial channel interactions in cochlear implantsJournal of Neural Engineering, 2011
- Effect of Stimulation Rate on Cochlear Implant Users’ Phoneme, Word and Sentence Recognition in Quiet and in NoiseAudiology and Neurotology, 2010
- Cortical activity patterns predict speech discrimination abilityNature Neuroscience, 2008
- Linking Cortical Spike Pattern Codes to Auditory PerceptionJournal of Cognitive Neuroscience, 2008
- Targeted bulk-loading of fluorescent indicators for two-photon brain imaging in vivoNature Protocols, 2006
- Auditory Learning and Adaptation after Cochlear Implantation: A Preliminary Study of Discrimination and Labeling of Vowel Sounds by Cochlear Implant UsersActa Oto-Laryngologica, 2001
- Cochlea in old world mice and rats (Muridae)Journal of Morphology, 1988