Evaluation of volume responsiveness by pulse pressure variability and inferior vena cava dispensability index at different tidal volumes by mechanical ventilation
Open Access
- 1 January 2019
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 52 (9) , e8827
Abstract
This study investigated the effects of tidal volume (TV) on the diagnostic value of pulse pressure variation (PPV) and the inferior vena cava dispensability index (IVC-DI) for volume responsiveness during mechanical ventilation. In patients undergoing elective surgery with mechanical ventilation, different TVs of 6, 9, and 12 mL/kg were given for two min. The left ventricular outflow tract velocity-time integral (VTI) was measured by transthoracic echocardiography. The IVC-DI was measured at sub-xyphoid transabdominal long axis. The PPV was measured via the radial artery and served as baseline. Index measurements were repeated after fluid challenge. VTI increased by more than 15% after fluid challenge, which was considered as volume responsive. Seventy-nine patients were enrolled, 38 of whom were considered positive volume responsive. Baseline data between the response group and the non-response group were similar. Receiver operating characteristic curve confirmed PPV accuracy in diagnosing an increase in volume responsiveness with increased TV. When TV was 12 mL/kg, the PPV area under the curve (AUC) was 0.93 and the threshold value was 15.5%. IVC-DI had the highest diagnostic accuracy at a TV of 9 mL/kg and an AUC of 0.79, with a threshold value of 15.3%. When TV increased to 12 mL/kg, the IVC-DI value decreased. When the TV was 9 and 12 mL/kg, PPV showed improved performance in diagnosing volume responsiveness than did IVC-DI. PPV diagnostic accuracy in mechanically ventilated patients was higher than IVC-DI. PPV accuracy in predicting volume responsiveness was increased by increasing TV.Keywords
This publication has 42 references indexed in Scilit:
- Fluid balance and cardiac function in septic shock as predictors of hospital mortalityCritical Care, 2013
- Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality*Critical Care Medicine, 2011
- Hemodynamic parameters to guide fluid therapyAnnals of Intensive Care, 2011
- The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgeryAnaesthesia, 2010
- Does perioperative hemodynamic optimization protect renal function in surgical patients? A meta-analytic studyCritical Care Medicine, 2009
- Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure*Critical Care Medicine, 2008
- Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trialCritical Care, 2007
- The Influence of Tidal Volume on the Dynamic Variables of Fluid Responsiveness in Critically Ill PatientsAnesthesia & Analgesia, 2006
- Changes in Arterial Pressure during Mechanical VentilationAnesthesiology, 2005
- Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic ShockThe New England journal of medicine, 2001