Seismic Behavior of Welded Beam-to-Column Joints of High-Strength Steel-Moment Frame with Replaceable Damage-Control Fuses
- 1 August 2020
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 146 (8) , 04020143
Abstract
This paper first proposes a high-strength (HS) steel-moment frame structure with replaceable damage-control fuses, which utilized the very large elastic deformation capacity of HS steel and damage-control functions of fuses. The damage is basically concentrated to fuses even under very rare earthquakes, and the damaged fuses can be easily replaced after earthquakes. A test program including 11 full-scale specimens was carried out to study the seismic behavior of HS steel beam-to-column joints either with or without fuses. The investigated parameters include different types of fuses, different thickness of the fuse plate, and different ways to strengthen the out-of-plane stiffness of fuse plates. The failure mode, deformation progress, hysteretic responses, skeleton curves, bending strengths, and energy-dissipation capacity of these full-scale tests were reported, analyzed, and discussed. Test results showed that the HS steel joints with fuses were able to provide large damage-free deformation. The application of proposed fuses in the HS steel-moment frame effectively shifted the damage from beam-to-column welds to replaceable fuse plates. Meanwhile, the shape of fuse plate exhibited marginal influence, but its thickness has significant influence on the T-joint. Formulas were proposed to estimate the yielding and ultimate bending strength of T-joint with fuses. Finally, a step-by-step procedure is given to design the proposed fuses.Keywords
This publication has 15 references indexed in Scilit:
- Cyclic testing of replaceable damper: Earthquake-resilient prefabricated column-flange beam-column jointEngineering Structures, 2019
- Development of a buckling-restrained shear panel damper with demountable steel-concrete composite restrainersSoil Dynamics and Earthquake Engineering, 2019
- Bolted Built-Up Columns Constructed of High-Strength Steel under Combined Flexure and CompressionJournal of Structural Engineering, 2017
- Experimental study on seismic behavior of high strength steel frames: Global responseEngineering Structures, 2017
- Field investigation on severely damaged aseismic buildings in 2014 Ludian earthquakeEarthquake Engineering and Engineering Vibration, 2015
- Evaluation of yielding shear panel device for passive energy dissipationJournal of Constructional Steel Research, 2009
- Experimental study of structure with “dual function” metallic dampersEngineering Structures, 2007
- Mechanical property of beam-to-column moment connection with hysteretic dampers for column weak axisEngineering Structures, 2005
- Classification of damage to steel buildings observed in the 1995 Hyogoken-Nanbu earthquakeEngineering Structures, 1998
- Seismic‐resistant steel moment connections: developments since the 1994 Northridge earthquakeProgress in Structural Engineering and Materials, 1997