Comparative Study on Thermal Performance of Ultrathin Miniature Loop Heat Pipes With Different Internal Wicks
- 27 June 2017
- journal article
- research article
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (12)
Abstract
Presented here are the results of an experimental investigation of two ultrathin miniature loop heat pipes (mLHPs) with different internal wicking structures: one with a primary wicking structure in the evaporator and a secondary wicking structure in the liquid line, and the other only with the same primary wicking structure in the evaporator, but no secondary wick. The systematic experimental investigation was conducted using natural convection as the cooling mechanism in order to study the heat transfer performance of the two mLHPs and fully examine the effects of the secondary wick. The results indicated that both of the test articles could effectively dissipate 12 W at all test orientations with a minimum total thermal resistances of 6.38 °C/W and 6.39 °C/W, respectively. However, the results indicated that the presence of the secondary wicking structure in the liquid line at low power loads resulted in more stable startup characteristics and a weaker dependence on the different orientations. Moreover, it was demonstrated that the steady-state evaporator temperatures of the test article with the secondary wicking structure in the liquid line were much lower than those observed for a 1-mm thick copper plate with the same geometric dimensions for all heat loads in the horizontal orientation, showing a higher thermal performance.Keywords
Funding Information
- National Natural Science Foundation of China (51176202)
- National Natural Science Foundation of China (51476161)
This publication has 14 references indexed in Scilit:
- LHP heat transfer performance: A comparison study about sintered copper powder wick and copper mesh wickApplied Thermal Engineering, 2016
- Experimental investigation on the sintered wick of the anti-gravity loop-shaped heat pipeExperimental Thermal and Fluid Science, 2015
- Operational characteristics of flat type loop heat pipe with biporous wickInternational Journal of Thermal Sciences, 2012
- A Compact Loop Heat Pipe With Flat Square Evaporator for High Power Chip CoolingIEEE Transactions on Components, Packaging and Manufacturing Technology, 2011
- 3D heat transfer analysis in a loop heat pipe evaporator with a fully saturated wickInternational Journal of Heat and Mass Transfer, 2011
- Heat transfer analysis of a loop heat pipe with biporous wicksInternational Journal of Heat and Mass Transfer, 2009
- Parametric analysis of loop heat pipe operation: a literature reviewInternational Journal of Thermal Sciences, 2007
- Miniature loop heat pipes-a promising means for cooling electronicsIEEE Transactions on Components and Packaging Technologies, 2005
- Loop heat pipesApplied Thermal Engineering, 2005
- Experimental and analytical investigation of a capillary pumped loopJournal of Thermophysics and Heat Transfer, 1994