Effects of 12‐Crown‐4 Ether on the Electrochemical Performance of CoO2 and TiS2 Cathodes in Li Polymer Electrolyte Cells

Authors:

Abstract
Polyethylene oxide (PEO) electrolytes appear stable in the potential range of 2.2 to 5.5 V vs. Li and the addition of 12‐Crown‐4 Ether (12Cr4) to enhance their conductivity does not seem to alter the electrochemical potential window. The dc cyclic voltammogram of cells of the type Li/PEO at low scan rate (1 mV/s) exhibits well‐defined cathodic and anodic peaks in the potential range from 2.2 to 5.5 V. The additive 12Cr4 improves the electrochemical performance of the cells as evidenced by lower peak splitting, higher current, and higher reversibility over many voltage scans. The open‐circuit voltage (OCV) of a freshly assembled cell in the discharged state is in the range from 3.5 to 3.7 V. Upon charging at the C/180 rate, which mimics a titration experiment (OCV vs. cathode composition), the OCV rises sharply to 4.1 V at then gradually increases to 4.4 V at . The titration curves are similar for cells with and without 12Cr4 in the electrolyte. The long term ac behavior of the cells (three‐electrode configuration with 0.7 cm2 Li counter; 0.06 cm2 working; and Li reference) shows that the addition of 12Cr4 reduces the bulk and interfacial charge‐transfer resistances but does not prolong the active life of the cells. While the cells with as the cathode fail after a couple of galvanostatic charge/discharge (c/d) cycles similar cells with did not fail even after 12 c/d cycles. As in the case of cells containing as cathode, 12Cr4 in the electrolyte improves the electrochemical performance of cells with as cathodes. The probable cause of failure in the case of is ascribed to the instability of the cathode.