Abstract
In vivo flexion-extension magnetic resonance imaging studies of the cervical spine were performed inside a positioning device. To determine the functional changes of the cervical cord and the subarachnoid space that occur during flexion and extension of the cervical spine in healthy individuals. As an addition to static magnetic resonance imaging examinations, kinematic magnetic resonance imaging studies of the cervical spine were performed to obtain detailed information about functional aspects of the cervical cord and the subarachnoid space. The results were compared with published data of functional flexion-extension myelograms of the cervical spine. The cervical spines of 40 healthy individuals were examined in a whole-body magnetic resonance scanner from 50° of flexion to 30° of extension, using a positioning device. At nine different angle positions, sagittal T1-weighted spin-echo sequences were obtained. The images were analyzed with respect to the segmental motion, the diameter of the subarachnoid space, and the diameter of the cervical cord. The segmental motion between flexion and extension was 11° at C2-C3, 12° at C3-C4, 15° at C4-C5, 19° at C5-C6, and 20° at C6-C7. At flexion, a narrowing of the ventral subarachnoid space of up to 43% and a widening of the dorsal subarachnoid space of up to 89% (compared with the neutral position, 0°) were observed. At extension, an increase in the diameter of the ventral subarachnoid space of up to 9% was observed, whereas the dorsal subarachnoid space was reduced to 17%. At flexion, there was a reduction in the sagittal diameter of the cervical cord of up to 14%, and, at extension, there was an increase of up to 15%, compared with the neutral position (0°; these values varied depending on the cervical segment. Statistically significant differences (P < 0.05) were found between flexion and extension in the diameter of the ventral and dorsal subarachnoid space and in the diameter of the cervical cord. Compared with the results of previous studies using functional cervical myelograms, kinematic magnetic resonance imaging provides additional noninvasive data concerning the physiologic changes of the cervical subarachnoid space and the cervical cord during flexion and extension in healthy individuals.Keywords
This publication has 15 references indexed in Scilit:
- Changes in Cervical Canal Spinal Volume During In Vitro Flexion-ExtensionSpine, 1996
- Endometriosis: Still an EnigmaRadiology, 1994
- Technical Note: “Dynamic” MRI Scanning of the Cervical SpineSpine, 1988
- Functional Radiographic Diagnosis of the Cervical Spine: Flexion/ExtensionSpine, 1988
- Dynamic evaluation of cervical spinal cord by magnetic resonance imaging: Improvement of indication for surgical treatment of chronic cervical myelopathyMagnetic Resonance Imaging, 1986
- PATHOGENESIS OF MYELOPATHY IN CERVICAL SPONDYLOSISThe Lancet, 1974
- The Mobility of the Cervical Spinal Cord under Normal ConditionsBritish Journal of Radiology, 1959
- The Clinical Manifestations of Spondylochondrosis (Spondylosis) of the Cervical Spine*Annals of Surgery, 1955
- Cross‐sectional diameters and areas of the human spinal cordThe Anatomical Record, 1945
- Air Myelography for Demonstration of the Cervical Spinal CordRadiology, 1942