Interventions Implemented to Reduce the Risk of Transmission of Bacteria by Transfusion in the English National Blood Service
- 1 January 2011
- journal article
- Published by S. Karger AG in Transfusion Medicine and Hemotherapy
- Vol. 38 (4) , 255-258
Abstract
Background: Bacterial contamination remains a significant problem in transfusion medicine. A National Health Service Blood and Transplant (NHSBT) study and surveillance data indicated skin commensals derived from the skin of the donor are the major contaminants of blood components. NHSBT therefore explored two interventions: improved donor arm disinfection and diversion. Methods: Improved donor arm disinfection: Commercial and in-house methods of disinfection were evaluated. Swabs at the venepuncture site were taken before and after disinfection and the reduction in bioburden determined. Diversion: Special collection bags were manufactured to allow the initial volume of blood to flow into a pouch, representing the diversion pouch and then the next flow of blood into another pouch representing the collection bag. Pouches were screened for the presence of bacteria. The reduction in bacterial contamination was then determined. Results: A two-step commercial procedure (Donor Prep Kit; DPK) consisting of 70% isopropyl alcohol followed by tincture of iodine was shown to be a best practice procedure (2-min procedure). A 99.79% reduction was obtained, and this method was 10 times more effective than current practice at that time. The DPK was shown in a field trial to increase donor waiting time. A second study was initiated to find a more rapid procedure. ChloraPrep®, consisting of 2% chlorhexidine gluconate and 70% isopropyl alcohol, was shown to have equivalent disinfection efficiency as the DPK, but only took 1 min to perform. In 2006, ChloraPrep was introduced as the national method of donor arm disinfection. Diversion was shown to give a 47% reduction in contamination and was introduced nationally in 2002. Conclusion: Improved donor arm disinfection and diversion are effective, low-cost interventions, but do not eliminate all bacterial transmissions. In 2011, bacterial screening of platelet components was introduced by NHSBT to further increase the safety of the blood supply.Keywords
This publication has 17 references indexed in Scilit:
- Skin disinfection with a single‐step 2% chlorhexidine swab is more effective than a two‐step povidone‐iodine method in preventing bacterial contamination of apheresis plateletsTransfusion, 2010
- A novel rapid and effective donor arm disinfection methodTransfusion, 2009
- Skin disinfection methods: prospective evaluation and postimplementation resultsTransfusion, 2009
- epic2: National Evidence-Based Guidelines for Preventing Healthcare-Associated Infections in NHS Hospitals in EnglandJournal of Hospital Infection, 2007
- Estimates of the frequency of HBV, HCV, and HIV infectious donations entering the blood supply in the United Kingdom, 1996 to 2003Eurosurveillance, 2005
- Proceedings of a Consensus Conference: Towards an Understanding of TRALITransfusion Medicine Reviews, 2005
- ORIGINAL PAPER. Relative values of the interventions of diversion and improved donor‐arm disinfection to reduce the bacterial risk from blood transfusionVox Sanguinis, 2004
- Evaluation of the 3D BacT/ALERT automated culture system for the detection of microbial contamination of platelet concentratesTransfusion Medicine, 2002
- Evaluation of donor skin disinfection methodsTransfusion, 1997
- FROZEN AND DRIED PLASMA FOR CIVIL AND MILITARY USEJAMA, 1941