Abstract
The aim of this study was to assess the dependence of the normal liver tissue threshold dose on the volume exposed and the catheter geometry-dependent dose gradients for single-fraction high-dose-rate brachytherapy of malignant liver lesions. A total of 50 patients with malignant liver tumors treated with CT-guided high-dose-rate 192Ir brachytherapy were included. Dose planning was performed using a three-dimensional CT data set acquired after percutaneous applicator positioning. Magnetic resonance imaging (MRI), performed 6 and 12 weeks after therapy, was analyzed retrospectively. All MRI data sets were merged with 3D dosimetry data. The border of hyperintensity on T2-weighted images (edema) and of hypointensity on T1-weighted images (impaired hepatocyte function) were analyzed to assess the radiation effect. The threshold isodose surface of the volume exposed was calculated from the 3D dosimetry data. The relationships between irradiated volume and threshold isodose surface as well as dose gradient and threshold isodose surface were evaluated over time. The median threshold dose of the volume exposed, characterized by hepatocyte dysfunction and edema, was approximately 13 Gy 6 weeks after irradiation and approximately 16 Gy at 12 weeks. We found a significant correlation between the normal liver tissue threshold dose and volume exposed (P < 0.0001). The 12-week threshold dose was estimated between approximately 14 Gy for 500 cm(3), approximately 16 Gy for 100 cm(3), and approximately 18 Gy for 10 cm(3) of irradiated volume. The results indicate that the dose gradient has no effect on the threshold liver dose. There was a significant shift of the threshold doses from regions of lower to regions of higher-dose exposure in the course of follow-up (P < 0.0001). Thus the normal liver tissue threshold dose is dependent on the volume exposed but not on the dose gradient.Keywords
This publication has 27 references indexed in Scilit:
- Stereotactic radiotherapy of primary liver cancer and hepatic metastasesActa Oncologica, 2006
- A phase I trial of stereotactic body radiation therapy (SBRT) for liver metastasesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- In vivo assessment of the tolerance dose of small liver volumes after single-fraction HDR irradiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Liver Malignancies: CT-Guided Interstitial Brachytherapy in Patients with Unfavorable Lesions for Thermal AblationJournal of Vascular and Interventional Radiology, 2004
- CT-guided interstitial brachytherapy of liver malignancies alone or in combination with thermal ablation: phase I–II results of a novel techniqueInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Assessment of focal liver reaction by multiphasic CT after stereotactic single-dose radiotherapy of liver tumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2003
- Stereotactic Single-Dose Radiation Therapy of Liver Tumors: Results of a Phase I/II TrialJournal of Clinical Oncology, 2001
- Mechanisms of Action of Liver Contrast Agents: Impact for Clinical UseJournal of Computer Assisted Tomography, 1999
- Gadobenate Dimeglumine (Gd-BOPTA)Investigative Radiology, 1998
- Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43Medical Physics, 1995