Mechanical axial instability of segmental pedicle screw instrumentation for adolescent idiopathic scoliosis: a retrospective cohort study of tulip screw versus dual locking cup instrumentation
Open Access
- 18 July 2025
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 96, 540–546
Abstract
Background and purpose: The effects of axial instability in the rod–screw interface resulting in axial slippage between screws and rods are largely unknown. We aimed to assess the incidence of axial slip and loss of correction by comparing tulip screw versus dual locking cup in spinal instrumentations of patients treated with posterior spinal fusion for adolescent idiopathic scoliosis (AIS). We also aimed to assess whether axial slip would affect health-related quality of life.Methods: This study consists of 194 patients who underwent posterior spinal fusion for AIS during 2012–2022. All patients had a minimum of 2 years’ follow-up. There were 98 patients treated with segmental tulip pedicle screw instrumentation and 96 patients with segmental dual locking cup constructs. Axial slip was defined as ≥ 2 mm and was assessed by measuring the rod exceeding the last pedicle screw and the distance between the 2 lowest screws on the same rod. Loss of correction was assessed by comparing postoperative and 2-year radiographic measurements. Health-related quality of life was assessed using the SRS-24 questionnaire.Results: Axial slip occurred only between the lowest instrumented vertebra and the vertebra above it on the convex side of the deformity. At 2 years of follow-up, axial slippage of 2 mm or more was observed more often in the dual locking group, which was observed in 24 (25%) patients in the dual locking cup group and 11 (11%) patients in the tulip group (risk ratio [RR] 2.2, 95% confidence interval [CI] 1.2–4.4). Minimum of 10° loss of major curve correction was found in 1 (1%) patient in the tulip group and 9 (9%) patients in the dual locking group (RR 9.1, CI 1.2–100).Conclusion: Axial slip was significantly less frequent in the tulip group than in the dual locking cup group. This suggests that tulip screw instrumentation may offer superior mechanical stability in posterior spinal fusion for AIS. Axial slip was not associated with health-related quality of life outcomes.Keywords
This publication has 19 references indexed in Scilit:
- Posterior Spinal Fusion With Pedicle Screws in Patients With Idiopathic Scoliosis and Open Triradiate Cartilage: Does Deformity Progression Occur?Journal of Pediatric Orthopaedics, 2016
- Spinal deformity progression after posterior segmental instrumentation and fusion for idiopathic scoliosisJournal of Children's Orthopaedics, 2015
- All-Pedicle Screw Versus Hybrid Instrumentation in Adolescent Idiopathic Scoliosis SurgerySpine, 2013
- Impact of Pedicle Screw Fixation on Loss of Deformity Correction in Patients With Adolescent Idiopathic ScoliosisJournal of Pediatric Orthopaedics, 2013
- Adolescent idiopathic scoliosisThe Lancet, 2008
- Outcomes of Surgical Treatment in Male Versus Female Adolescent Idiopathic Scoliosis PatientsSpine, 2007
- Loss of Coronal Correction Following Instrumentation Removal in Adolescent Idiopathic ScoliosisSpine, 2006
- Adolescent idiopathic scoliosis: a new classification to determine extent of spinal arthrodesis.2001
- Results of the Scoliosis Research Society Instrument for Evaluation of Surgical Outcome in Adolescent Idiopathic ScoliosisSpine, 1999
- The Measurement of Observer Agreement for Categorical DataBiometrics, 1977