The analysis of pesticides in food products requires accurate measurements for which standardised protocols have been developed. This paper reports the validation of QuEChERS (quick, easy, cheap, effective, rugged, and safe)-based methods applied to three different food samples (brown rice, red pepper and mandarin orange) analysed using gas chromatography-tandem mass spectrometry (GC-MS/MS). The validation of the analytical methods used to measure 113 pesticides, including various insecticides, fungicides and herbicides, was conducted in three food matrices and at three spiking levels by three different laboratories. The set of validated results was interpreted, statistically analysed and visualised using principal component analysis (PCA). Notably, the matrix effects in GC-MS analysis for most of the tested pesticides from different matrices were lowered to practical values (less than 30%) appropriate for routine analysis. This allowed for the quantification of pesticides in the samples using standard and analyte protectants (APs) in the reagent method blank as a screening measure, providing an alternative to matrix-matched calibration. Alternatively, the use of only one standardised calibration (grape matrix) in combination with APs also allowed for the qualitative and semi-quantitative analysis of pesticides in different matrices. The inclusion of APs reduced the differences in the matrix-induced enhancement effects of various samples. The use of an internal standard (IS) to correct the matrix effects was also noted. The normalisation of the analyte peak with triphenyl phosphate (TPP) as an IS resulted in a slight improvement of validation values such as precision and linearity in only one laboratory, but it lowered the value of matrix effects in all three laboratories.Keywords
This publication has 17 references indexed in Scilit:
- Clean-up of cereal extracts for gas chromatography–tandem quadrupole mass spectrometry pesticide residues analysis using primary secondary amine and C18Journal of Chromatography A, 2015
- Multi-residue pesticide analysis (gas chromatography–tandem mass spectrometry detection)—Improvement of the quick, easy, cheap, effective, rugged, and safe method for dried fruits and fat-rich cereals—Benefit and limit of a standardized apple purée calibration (screening)Journal of Chromatography A, 2015
- Variability of matrix effects in liquid and gas chromatography–mass spectrometry analysis of pesticide residues after QuEChERS sample preparation of different food cropsJournal of Chromatography A, 2012
- Compensation for matrix effects in the gas chromatography–mass spectrometry analysis of 186 pesticides in tea matrices using analyte protectantsJournal of Chromatography A, 2012
- Development of a fast multiresidue method for the determination of pesticides in dry samples (wheat grains, flour and bran) using QuEChERS based method and GC–MSFood Chemistry, 2011
- Determination of 23 pesticide residues in leafy vegetables using gas chromatography–ion trap mass spectrometry and analyte protectantsJournal of Chromatography A, 2008
- Evaluation of a solid-phase extraction dual-layer carbon/primary secondary amine for clean-up of fatty acid matrix components from food extracts in multiresidue pesticide analysisJournal of Chromatography A, 2007
- Combination of Analyte Protectants To Overcome Matrix Effects in Routine GC Analysis of Pesticide Residues in Food MatrixesAnalytical Chemistry, 2005
- Use of automated direct sample introduction with analyte protectants in the GC–MS analysis of pesticide residuesJournal of Separation Science, 2005
- Evaluation of analyte protectants to improve gas chromatographic analysis of pesticidesJournal of Chromatography A, 2003