Abstract
A preterm newborn infant, delivered at 30 weeks of gestation and 965 g birth weight, developed respiratory distress with resistant hypoxia after a central catheter line was inserted via the right venae brachialis on postnatal day 21. Left‐sided massive pleural effusion, collapsed left lung with air bronchograms, and bidirectional shunting through reopened ductus arteriosus were detected by targeted neonatal echocardiography. Hydrothorax was drained under sonographic guidance, producing a milky‐white fluid biochemically compatible with parenteral nutrition. We report this case of hydrothorax secondary to a misplaced central catheter on the contralateral side of its peripheral insertion. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 46:140–144, 2018