A comparison of two data analyses from two observer performance studies using JackknifeROCandJAFROC
- 22 March 2005
- journal article
- Published by Wiley in Medical Physics
- Vol. 32 (4) , 1031-1034
Abstract
The authors compared two methodological approaches, Jackknife ROC and JAFROC, in analyzing data ascertained during FROC (free-response receiver operating characteristics) type studies. Observer rating data obtained from two observer performance studies were analyzed. During the first study, seven radiologists interpreted 120 mammography examinations depicting 57 masses under five different conditions with and without the results of computer-aided detection (CAD). In the second study, eight radiologists interpreted 110 examinations depicting 51 masses under six different display conditions with and without CAD results. Readers rated the detection task in a FROC type response. Jackknife ROC (using the software of LABMRMC with the highest rating per case) and JAFROC were used to compute differences, if any, in summary performance levels among all reading modes in each study as well as for all paired data sets. The results of the different analytical approaches are compared. The overall results for all modes were significantly different for the first study (p < 0.05) and not significant (p > 0.05) for the second study using either analytical approach. In the first study, the performance levels represented by three paired data sets were significantly different (p < 0.05) when computed using LABMRMC and four pairs were significantly different (p < 0.05) using JAFROC. In eight of ten pairs, JAFROC produced lower p values than LABMRMC. In the second study, LABMRMC showed no significant differences for any paired data sets and JAFROC showed a significant difference for one pair. In 15 of 16 pairs, p values computed by JAFROC were lower than those computed by LABMRMC.Keywords
Funding Information
- National Cancer Institute (CA77850)
- National Institutes of Health (CA79754)
This publication has 10 references indexed in Scilit:
- Radial gradient‐based segmentation of mammographic microcalcifications: Observer evaluation and effect on CAD performanceMedical Physics, 2004
- Observer studies involving detection and localization: Modeling, analysis, and validationMedical Physics, 2004
- Detection and classification performance levels of mammographic masses under different computer-aided detection cueing environments1Academic Radiology, 2004
- ROC-Type Assessments of Medical Imaging and CAD Technologies: A PerspectiveAcademic Radiology, 2003
- Assessment of Medical Imaging and Computer-Assist SystemsAcademic Radiology, 2002
- Breast Cancer: Effectiveness of Computer-aided Diagnosis—Observer Study with Independent Database of MammogramsRadiology, 2002
- Statistical Power in Observer-Performance Studies: Comparison of the Receiver Operating Characteristic and Free-Response Methods in Tasks Involving LocalizationAcademic Radiology, 2002
- Soft-Copy Mammographic Readings with Different Computer-assisted Detection Cuing Environments: Preliminary FindingsRadiology, 2001
- Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: Validation with computer simulationAcademic Radiology, 1997
- Receiver Operating Characteristic Rating AnalysisInvestigative Radiology, 1992