Transcranial Doppler Velocities and Angiographic Vasospasm after SAH: A Diagnostic Accuracy Study
- 18 November 2021
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (1) , 80-86
Abstract
BACKGROUND AND PURPOSE: After aneurysmal SAH, transcranial Doppler is commonly used to monitor cerebral vasospasm. The diagnostic accuracy of transcranial Doppler flow velocity values in detecting angiographic vasospasm in patients requiring urgent endovascular intervention has not been established. MATERIALS AND METHODS: We performed a retrospective analysis of a consecutive series of patients with aneurysmal SAH who underwent transcranial Doppler (index test) within 24 hours of conventional angiography (reference test). The judgment of 33%, 50%, and 66% degree of vessel narrowing on angiography was independently established by multiple neuroendovascular clinicians. Vessel-specific per-segment and per-patient transcranial Doppler velocities were studied using receiver operating characteristic curves, the Youden index, and minimal acceptable sensitivity models. Optimal mean flow-velocity thresholds were explored to calculate sensitivity and specificity using a per-patient judgment of vasospasm of at least 50% angiographic narrowing in any large arterial segment except A1. RESULTS: In 221 patients, vasospasm was found in 15%, 8%, and 4% of arteries when the degree of reference angiographic luminal narrowing was 33%, 50%, and 66%, respectively. Mean flow velocities were significantly higher in vasospastic segments (P = . 001), but per-segment exploratory analyses yielded unsound mean flow velocity thresholds. The Youden and minimal acceptable sensitivity models proposed mean flow velocity thresholds of approximately 160 cm/s for the anterior circulation and 80 cm/s for the posterior circulation in the per-patient diagnosis of angiographic vasospasm (≥50%), yielding a sensitivity of 80%–90% (95% CI, 0.77–0.96), but with a corresponding specificity of 50% (95% CI, 0.40–0.56). CONCLUSIONS: In this study, a threshold transcranial Doppler mean flow-velocity value that would accurately diagnose ≥50% angiographic vasospasm remained elusive.Keywords
This publication has 26 references indexed in Scilit:
- American Society of Neurophysiologic Monitoring and American Society of Neuroimaging Joint Guidelines for Transcranial Doppler Ultrasonic MonitoringJournal of Neuroimaging, 2011
- Defining Vasospasm After Subarachnoid HemorrhageStroke, 2009
- Vasospasm probability index: a combination of transcranial Doppler velocities, cerebral blood flow, and clinical risk factors to predict cerebral vasospasm after aneurysmal subarachnoid hemorrhageJournal of Neurosurgery, 2007
- Transcranial Doppler Versus Angiography in Patients With Vasospasm due to a Ruptured Cerebral AneurysmStroke, 2001
- Role of Transcranial Doppler Monitoring in the Diagnosis of Cerebral Vasospasm after Subarachnoid HemorrhageNeurosurgery, 1999
- Is routine transcranial Doppler ultrasound monitoring useful in the management of subarachnoid hemorrhage?Journal of Neurosurgery, 1998
- Causes of Morbidity and Mortality After Ruptured Aneurysm Surgery in a Series of 230 PatientsStroke, 1995
- Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteriesJournal of Neurosurgery, 1982
- Fluid Mechanics of Arterial StenosesJournal of Biomechanical Engineering, 1979
- Time course of vasospasm in manJournal of Neurosurgery, 1978