Comparing patient-centered outcomes and efficiency of space closure between nickel-titanium closed-coil springs and elastomeric power chains during orthodontic treatment:
Authors:
- Serene A. BadranSBSerene A. Badran
- Juman M. Al-ZabenJAJuman M. Al-Zaben
- Lina M. Al-TaieLALina M. Al-Taie
- Haya TbeishiHTHaya Tbeishi
- Mahmoud K. Al-OmiriMAMahmoud K. Al-Omiri
Open Access
- 1 July 2022
- journal article
- research article
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 92 (4) , 471-477
Abstract
Objectives: To compare patient-reported pain, discomfort, and difficulty in maintaining proper brushing between nickel-titanium closed-coil springs (CS) and elastomeric power chains (PC) when used for space closure. The secondary aims were to compare plaque control and efficiency of space closure between these two force delivery systems. Materials and Methods: A total of 48 patients who required extractions of upper first premolars and distal movement of upper canines had the CS randomly allocated to either the right or left side. Blinding was applied at data collection and analysis. Primary outcomes were pain intensity measured on visual analog scale, pain onset and duration, discomfort, and difficulty in maintaining proper brushing from the start of canine retraction at baseline and at 6 and 12 weeks thereafter. Secondary outcomes were plaque scores and the rate of space closure. Results: No significant differences in mean pain scores, pain onset, and duration at different time intervals between CS and PC were observed. The CS side was significantly less comfortable than the PC ( P < .0001) and more difficult to keep clean ( P = .008). No significant differences in plaque scores were observed between CS and PC groups at any time interval. CS produced a faster rate of space closure than did PC ( P = .008). Conclusions: CS were less tolerated than PC by patients but produced an average of 0.5 mm more movement than did the PC during the 12-week study period.Keywords
This publication has 24 references indexed in Scilit:
- Factors influencing efficiency of sliding mechanics to close extraction space: a systematic reviewOrthodontics & Craniofacial Research, 2008
- Perception of pain during orthodontic treatment with fixed appliancesEuropean Journal of Orthodontics, 2004
- A clinical investigation of force delivery systems for orthodontic space closureJournal of Orthodontics, 2003
- A randomized clinical trial to compare three methods of orthodontic space closureJournal of Orthodontics, 2002
- Perception of pain as a result of orthodontic treatment with fixed appliancesEuropean Journal of Orthodontics, 1996
- GPOWER: A general power analysis programBehavior Research Methods, Instruments, & Computers, 1996
- Perception of pain as a result of orthodontic treatment with fixed appliancesEuropean Journal of Orthodontics, 1996
- Force degradation of orthodontic elastomeric chains—A product comparison studyAmerican Journal of Orthodontics, 1985
- The Plaque Control RecordJournal of Periodontology, 1972
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionActa Odontologica Scandinavica, 1964