Abstract
It is shown in this paper that the commonly used method for converting from standard single-ended to mixed- mode S-parameters for networks with differential signaling only works for odd- and even-mode impedance equal to 50Omega. A correct conversion matrix equation must include the odd- and even-mode impedances which are not equal to the unique characteristic impedance owing to signal coupling in the network.