Feasibility of an alternative method to estimate glenohumeral joint center from videogrammetry measurements and CT/MRI of patients
- 26 August 2020
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 24 (1) , 33-42
Abstract
Videogrammetry is commonly used to record upper limb motions. However, it cannot track the glenohumeral joint center (GH). GH is required to reconstruct upper limb motions. Therefore, it is often estimated by separately measuring scapular motions using scapular kinematics measurements devices (SKMD). Applications of SKMD are neither straightforward nor always noninvasive. Therefore, this work investigates the feasibility of an alternative method to estimate GH from videogrammetry using a CT/MRI image of subject’s glenohumeral joint and without requiring SKMD. In order to evaluate the method’s accuracy, its GH estimations were compared to reference GH trajectories. The method was also applied to estimate scapular configurations and reconstruct an abduction motion measured by videogrammetry. The accuracy of GH estimations were within 5 mm, and the reconstructed motion was in good agreement with reported in vivo measurements.Keywords
Funding Information
- Swiss National Science Foundation
- This work was funded by Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
This publication has 49 references indexed in Scilit:
- Kinematic models of the upper limb joints for multibody kinematics optimisation: An overviewJournal of Biomechanics, 2017
- Main component of soft tissue artifact of the upper-limbs with respect to different functional, daily life and sports movementsJournal of Biomechanics, 2017
- Can optimal marker weightings improve thoracohumeral kinematics accuracy?Journal of Biomechanics, 2015
- MRI development and validation of two new predictive methods of glenohumeral joint centre location identification and comparison with established techniquesJournal of Biomechanics, 2009
- A mathematical musculoskeletal shoulder model for proactive ergonomic analysisComputer Methods in Biomechanics and Biomedical Engineering, 2007
- An optimized protocol for hip joint centre determination using the functional methodJournal of Biomechanics, 2006
- Convex Optimization2004
- A three-dimensional regression model of the shoulder rhythmClinical Biomechanics, 2001
- Velocity effects on the scapulo-humeral rhythmClinical Biomechanics, 1998
- A solidification procedure to facilitate kinematic analyses based on video system dataJournal of Biomechanics, 1995