Evaluating Pulmonary Function: An Assessment of Pao 2/Fio 2
Authors:
- Richard B. WeiskopfRWRichard B. Weiskopf
- 1 January 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 45 (1) , e40-e48
Abstract
Objectives: Pao 2/Fio 2 is used commonly for diagnosis of lung injury (acute respiratory distress syndrome and transfusion-related acute lung injury), for assessment of pulmonary disease course and therapy, and in pulmonary transplantation for evaluation of donor lungs and clinical outcome. It was developed for convenience, without formal mathematical and graphic assessment to validate its suitability for these purposes. Design: We examined, mathematically and graphically, the relationship of Pao 2/Fio 2 to Fio 2 at constant normal and several degrees of increased intrapulmonary shunting (Qs/Qt ), assessing the impact of intra- and extrapulmonary factors on the relationship and thus the reliability of Pao 2/Fio 2. Measurements and Main Results: The relationship of Pao 2/Fio 2 varies at all shunt fractions but most with Qs/Qt from 0.1 to 0.3 with Fio 2 approximately greater than 0.4. At higher Qs/Qt , the relationship is more constant and changes less with Fio 2 more than 0.4. Hemoglobin concentration and arterial-venous oxygen content difference have large effects that can confound interpretation of Pao 2/Fio 2. Barometric pressure has a substantial effect; Pco 2, base excess, and respiratory quotient have small effects. Conclusions: At high Qs/Qt with Fio 2 more than 0.4, the relationship of Pao 2/Fio 2 to Fio 2 is relatively constant. However, with Qs/Qt of 0.1–0.3, Pao 2/Fio 2 changes substantially with Fio 2. Understanding the important effects of nonpulmonary factors (especially hemoglobin concentration and arterial-venous oxygen content difference) should enhance appropriate clinical use, interpretation of Pao 2/Fio 2, and interpretation of previous publications and future studies (especially those seeking to assess effects of anemia or transfusion on lung function). The ratio of Pao 2/Fio 2 is a good tool for some, but not many clinical circumstances, and is insufficiently robust for most research applications.Keywords
This publication has 27 references indexed in Scilit:
- Variation in the PaO2/FiO2 ratio with FiO2: mathematical and experimental description, and clinical relevanceCritical Care, 2007
- Report of the ISHLT Working Group on Primary Lung Graft Dysfunction Part II: Definition. A Consensus Statement of the International Society for Heart and Lung TransplantationThe Journal of Heart and Lung Transplantation, 2005
- Variability of indices of hypoxemia in adult respiratory distress syndromeCritical Care Medicine, 1997
- The American-European Consensus Conference On Ards. Definitions, Mechanisms, Relevant Outcomes, And Clinical Trial CoordinationAmerican Journal of Respiratory and Critical Care Medicine, 1994
- Oxygen derived variables in acute respiratory failureCritical Care Medicine, 1983
- Extrapulmonary factors influencing the ratio of arterial oxygen tension to inspired oxygen concentration in burn patientsCritical Care Medicine, 1979
- The effect of PEEP on oxygenating capacity in acute respiratory failure with sepsisCritical Care Medicine, 1976
- Pulmonary Response to Major InjuryArchives of Surgery, 1974
- Respiratory Failuire in ShockAnnals of Surgery, 1969
- The lung as a black boxCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1966