Semi-automated measurement of hyperdense, hypodense and heterogeneous hepatic metastasis on standard MDCT slices. Comparison of semi-automated and manual measurement of RECIST and WHO criteria
Authors:
- 4 June 2008
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 18 (11) , 2456-2465
Abstract
As semi-automated measurement would be desirable for lesion quantification and therapy-response control, the purpose of this study was to compare semi-automated measurements with manual assessment of different types of hepatic metastases. Seventy-six patients with known liver metastases were analysed. All of them underwent contrast-enhanced 16-MDCT (16 × 0.75 mm collimation, 120 kV, 0.5 s rotation time, 160 mAseff) for evaluation of follow-up status. On the basis of standard reconstructed 5-mm slices (in 4-mm increments), each lesion was quantified based on RECIST and WHO criteria using a semi-automated software tool (Syngo Oncology) and also manually by an experienced radiologist. Results from the software were compared to manual measurements. Statistical analysis was performed applying the concordance correlation coefficient, and results were represented graphically in Bland-Altman plots. A total of 52 hyperdense, 57 hypodense and 56 heterogeneous metastases were found and correctly measured by the software. All three lesion types revealed a strong correlation agreement between measurement techniques [RECIST diameter: 0.93 (hyperdense), 0.95(hypodense), 0.94 (heterogeneous); WHO area: 0.95, 0.98, 0.93]. Semi-automatic measurement of hyperdense, hypodense and heterogeneous liver metastases showed reliable results on standard axial reconstructions in comparison to manual quantification.Keywords
This publication has 24 references indexed in Scilit:
- The use of 18F-FDG PET/CT in colorectal liver metastases—comparison with CT and liver MRIEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- OncoTREAT: a software assistant for cancer therapy monitoringInternational Journal of Computer Assisted Radiology and Surgery, 2006
- Shape-Constraint Region Growing for Delineation of Hepatic Metastases on Contrast-Enhanced Computed Tomograph ScansInvestigative Radiology, 2006
- Reproducibility of Computer-Aided Volumetry of Artificial Small Pulmonary Nodules in Ex Vivo Porcine LungsInvestigative Radiology, 2006
- Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteriaEuropean Radiology, 2005
- Monitoring of liver metastases after stereotactic radiotherapy using low-MI contrast-enhanced ultrasound?initial resultsEuropean Radiology, 2005
- Phase II Studies of Modern Drugs Directed Against New Targets: If You Are Fazed, Too, Then Resist RECISTJournal of Clinical Oncology, 2004
- New Guidelines to Evaluate the Response to Treatment in Solid TumorsJNCI: Journal of the National Cancer Institute, 2000
- Small Pulmonary Nodules: Evaluation with Repeat CT—Preliminary ExperienceRadiology, 1999
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986