Evaluation of Correction Methods for Determining Load-Independent Knoop Microhardness
Authors:
- 1 May 1978
- journal article
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 6 (3) , 221-230
Abstract
The correction methods proposed in the literature for determining load-independent Knoop microhardness were surveyed. The methods were evaluated by using the results from seven samples and two testers. Adding a constant correction factor for each sample to the measured long diagonals to obtain the unrecovered diagonal lengths was found to be quite successful. The correction factor includes terms from elastic recovery, visibility error, and calibration error. This factor, when applied, corrects the elastic recovery in the diagonals and the systematic errors associated with the tester employed, and thus results in Knoop hardness numbers independent of load and tester, which can be taken as the true hardness. The correction factor is load-independent but varies with sample and tester. Two methods in the literature, a trial and error approach and an extrapolation technique, were found to work equally well for the seven samples in determining the correction factors and the load-independent hardness numbers. The approach attempting to correct the applied load with a term representing the minimum indenting load proved to be unsatisfactory.Keywords
This publication has 4 references indexed in Scilit:
- An analysis of Knoop microhardnessMetallography, 1973
- MICROHARDNESS PHENOMENA IN SILVER. Technical Progress Report.1971
- Mechanical metallurgy.1961
- PROGRESS IN MICRO-INDENTATION HARDNESS TESTINGMetallurgical Reviews, 1959