Interleaved spiral‐in/out with application to functional MRI (fMRI)
Open Access
- 15 May 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (3) , 829-834
Abstract
The conventional spiral‐in/out trajectory samples k‐space sufficiently in the spiral‐in path and sufficiently in the spiral‐out path to enable creation of separate images. We propose an “interleaved spiral‐in/out” trajectory comprising a spiral‐in path that gathers one half of the k‐space data, and a complimentary spiral‐out path that gathers the other half. The readout duration is thereby reduced by approximately half, offering two distinct advantages: reduction of signal dropout due to susceptibility‐induced field gradients (at the expense of signal‐to‐noise ratio [SNR]), and the ability to achieve higher spatial resolution when the readout duration is identical to the conventional method. Two reconstruction methods are described; both involve temporal filtering to remove aliasing artifacts. Empirically, interleaved spiral‐in/out images are free from false activation resulting from signal pileup around the air/tissue interface, which is common in the conventional spiral‐out method. Comparisons with conventional methods using a hyperoxia stimulus reveal greater frontal‐orbital activation volumes but a slight reduction of overall activation in other brain regions. Magn Reson Med, 2009.Keywords
Funding Information
- National Institutes of Health (RR 09784)
- Lucas Foundation
- GE Health Care
This publication has 25 references indexed in Scilit:
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- Self‐calibrated spiral SENSEMagnetic Resonance in Medicine, 2004
- Improved combination of spiral‐in/out images for BOLD fMRIMagnetic Resonance in Medicine, 2004
- EPI‐BOLD fMRI of human motor cortex at 1.5 T and 3.0 T: Sensitivity dependence on echo time and acquisition bandwidthJournal of Magnetic Resonance Imaging, 2003
- Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortexMagnetic Resonance in Medicine, 2003
- Sensitivity‐encoded single‐shot spiral imaging for reduced susceptibility artifacts in BOLD fMRIMagnetic Resonance in Medicine, 2002
- Using UNFOLD to remove artifacts in parallel imaging and in partial‐Fourier imagingMagnetic Resonance in Medicine, 2002
- Compensation of Susceptibility-Induced BOLD Sensitivity Losses in Echo-Planar fMRI ImagingNeuroImage, 2002
- Analysis of fMRI Time-Series Revisited—AgainNeuroImage, 1995
- Reduction of susceptibility artifact in gradient‐echo imagingMagnetic Resonance in Medicine, 1992