Mass spectrometry imaging of surface lipids on intact Drosophila melanogaster flies
- 17 February 2014
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 49 (3) , 223-232
Abstract
The spatial distribution of neutral lipids and semiochemicals on the surface of six‐day‐old separately reared naive Drosophila melanogaster flies has been visualized and studied using matrix‐assisted laser desorption/ionization‐time of flight (MALDI‐TOF) mass spectrometry and laser‐assisted desorption/ionization (LDI)‐TOF imaging (MSI). Metal targets were designed for two‐dimensional MSI of the surface of 3‐D biological objects. Targets with either simple grooves or profiled holes designed to accurately accommodate the male and female bodies were fabricated. These grooves and especially holes ensured correct height fixation and spatial orientation of the flies on the targets after matrix application and sample drying. For LDI‐TOF to be used, the flies were arranged into holes and fixed to a plane of the target using fast‐setting glue. In MALDI‐TOF mode, the flies were fixed as above and sprayed with a lithium 2,5‐dihydroxybenzoate matrix using up to 100 airbrush spray cycles. The scanning electron microscopy images revealed that the deposits of matrix were homogenous and the matrix formed mostly into the clusters of crystals (40–80 µm) that were separated from each other by an uncovered cuticle surface (30–40 µm). The MSI using target with profiled holes provided superior results to the targets with simple grooves, eliminating the ion suppression/mass deviation due to the 3‐D shape of the flies. Attention was paid to neutral lipids and other compounds including the male anti‐attractant 11‐cis‐vaccenyl acetate for which the expected distribution with high concentration on the tip of the male abdomen was confirmed. The red and blue mass shift (PlusMinus1 colour scale) was observed associated with mass deviation predominantly between ±0.2 and 0.3 Da. We use in‐house developed software for mass recalibration, to eliminate the mass deviation effects and help with the detection of low‐intensity mass signals. Copyright © 2014 John Wiley & Sons, Ltd.Keywords
This publication has 33 references indexed in Scilit:
- Multiplexed Imaging of Nanoparticles in Tissues Using Laser Desorption/Ionization Mass SpectrometryJournal of the American Chemical Society, 2013
- Mass spectrometry imaging with high resolution in mass and spaceHistochemistry and Cell Biology, 2013
- Poly[N-(2-hydroxypropyl)methacrylamide]-Based Tissue-Embedding Medium Compatible with MALDI Mass Spectrometry Imaging ExperimentsAnalytical Chemistry, 2011
- Automated Ambient Desorption−Ionization Platform for Surface Imaging Integrated with a Commercial Fourier Transform Ion Cyclotron Resonance Mass SpectrometerAnalytical Chemistry, 2009
- Mass spectrometric imaging of lipids using desorption electrospray ionizationJournal of Chromatography B, 2009
- A New Male Sex Pheromone and Novel Cuticular Cues for Chemical Communication in DrosophilaCurrent Biology, 2009
- Nonuniform distribution of glucosinolates in Arabidopsis thaliana leaves has important consequences for plant defenseProceedings of the National Academy of Sciences, 2008
- Exciton Mobility and Trapping in a MALDI MatrixThe Journal of Physical Chemistry A, 2005
- Matrix‐assisted laser desorption/ionization analysis of lipids and high molecular weight hydrocarbons with lithium 2,5‐dihydroxybenzoate matrixRapid Communications in Mass Spectrometry, 2003
- Least Median of Squares RegressionJournal of the American Statistical Association, 1984