Surface porous fibre-reinforced composite bulk bone substitute
- 1 December 2004
- journal article
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 5 (4) , 213-221
Abstract
The aim of this study was to describe and evaluate the significance of a porous surface with bioactive glass granules (S53P4) covering an artificial bulk material based on polymethylmetacrylate (PMMA) and fibre-reinforced composite (FRC) technology. Effort was focused particularly on characters of the porous surface and biomechanical properties of the material in vitro, and test in vivo the implant in reconstruction in an experimental long bone segment defect model. The defect, 10 mm in length, created in the shaft of rabbit tibia, was reconstructed by the implant and fixed by intramedullary K-wires. The implant was incorporated within 4 weeks by new bone growth from the host bone covering particularly its posterior surface and cortex/implant junctions with bridging trabecular bone. Later, at 8 weeks, new bone was found also at the cortex/implant interface and in the medullary canal of the implant. Histometric measurements revealed direct bone/implant surface contact in 34% at the interface. Bioactive glass granules in the porous surface evoked the most direct contact with bone. The implants manufactured from PMMA only served as a control group, and showed significantly lower osteoconductive properties. Biomechanical measurements in vitro of fibre-reinforced PMMA specimens revealed values for bending strength and the flexural modulus to match them to human bone. This artificial bulk bone material based on PMMA/FRC technology seems to have proposing properties to be used as a bone substitute on load-bearing conditions.Keywords
This publication has 15 references indexed in Scilit:
- Biologic significance of surface microroughing in bone incorporation of porous bioactive glass implantsJournal of Biomedical Materials Research Part A, 2003
- Relative Contributions of Chemistry and Topography to the Osseointegration of Hydroxyapatite CoatingsClinical Orthopaedics and Related Research, 2002
- Repair of segmental bone defects using bioactive bone cement: Comparison with PMMA bone cementJournal of Biomedical Materials Research, 1999
- Release of residual methyl methacrylate into water from glass fibre-poly(methyl methacrylate) composite used in denturesBiomaterials, 1997
- Polymethylmethacrylate composites: disturbed bone formation at the surface of bioactive glass and hydroxyapatiteBiomaterials, 1996
- Repair of Massive Allografts: Histological, Nuclear Medicine and CT-Studies1996
- Residual monomer content and its release into water from denture base materialsDental Materials, 1995
- A new bioactive bone cement consisting of BIS‐GMA resin and bioactive glass powderJournal of Applied Biomaterials, 1993
- Mechanical properties of metaphyseal bone in the proximal femurJournal of Biomechanics, 1991
- A method for the study of undecalcified bones and teeth with attached soft tissues*Journal of Oral Pathology & Medicine, 1982