Abstract
Calculation of pressures in a soil body due to finite loads imposed on the soil surface is a necessary step in the design and analysis of buried commodities. This study compares two commonly-applied numerical methods used to develop the vertical soil pressure profiles applied to buried pipes. The methods compared in this study differ in theory, basis, assumptions, complexity, and results, and therefore the comparison is meaningful. Provided is a comparison between design vertical forces on different sizes of buried pipes at a range of soil depth, determined using an integration of Boussinesq’s equation [1] and the method specified by AASHTO [2]. The Boussinesq equation is defined as a function of location in varying two dimensional soil planes and the integration is performed over the boundary of the pipe as well as the applied soil surface footprint. The soil surface loading considered in this study includes the AASHTO Design Truck and the AASHTO Design Tandem, positioned as required by the AASHTO LRFD code [2]. Recommendations for application of the results is provided based upon the resulting force magnitude calculated and ease of application of the methods. Consideration of the effects of redistribution of loading due to pavements or other rigid surfaces is outside the scope of this study.