Application of synchrotron x-ray microtomography to investigate ductile fracture in Al alloys
Authors:
- 6 December 2005
- journal article
- conference paper
- Published by AIP Publishing in Applied Physics Letters
- Vol. 87 (24) , 241907
Abstract
The in situ high-resolution synchrotron x-ray computed microtomography has been applied to visualize and quantify the ductile fracture process of a notched Al alloy specimen. The three-dimensional (3D) investigation reveals that voids are nucleated, grow and coalesce more easily near the notch front and in the central region of the sample. These voids are mainly associated with Si particles in the eutectic (EU) phase. The 3D packing architecture of particles in the EU region, and the 3D morphology of phase are also visualized. The feasibility of this technique highlights the potential of its application in the field of micromechanics-based fracture.
Keywords
This publication has 19 references indexed in Scilit:
- X-ray computed microtomography of internal damage in fiber reinforced polymer matrix compositesComposites Science and Technology, 2005
- In-situ Observations of Fracture Processes in 0.6 μm and 9.5 μm SiCP/6061Al CompositesMATERIALS TRANSACTIONS, 2005
- A 3D measurement procedure for internal local crack driving forces via synchrotron X-ray microtomographyActa Materialia, 2004
- In-situ SEM study of fatigue crack growth behaviour in IN718International Journal of Fatigue, 2004
- Fracture behaviour and fracture toughness of ductile closed-cell metallic foamsActa Materialia, 2002
- Spatial distribution of voids in HY-100 steel by X-ray tomographyScripta Materialia, 2001
- Compressive deformation and yielding mechanisms in cellular Al alloys determined using X-ray tomography and surface strain mappingActa Materialia, 1998
- Three dimensional morphology of cementite precipitatesScripta Materialia, 1997
- High energy high resolution monochromatic x-ray computed tomography using the Photon Factory vertical wiggler beamlineReview of Scientific Instruments, 1992
- Three-Dimensional X-Ray MicrotomographyScience, 1987