A dosimetric characterization of a novel linear accelerator collimator
Authors:
- 28 February 2014
- journal article
- Published by Wiley in Medical Physics
- Vol. 41 (3) , 031713
Abstract
Purpose:: The aim of this work is to characterize a new linear accelerator collimator which contains a single pair of sculpted diaphragms mounted orthogonally to a 160 leaf multileaf collimator (MLC). The diaphragms have “thick” regions providing full attenuation and “thin” regions where attenuation is provided by both the leaves and the diaphragm. The leaves are mounted on a dynamic leaf guide allowing rapid leaf motion and leaf travel over 350 mm.Methods:: Dosimetric characterization, including assessment of leaf transmission, leaf tip transmission, penumbral width, was performed in a plotting tank. Head scatter factor was measured using a mini‐phantom and the effect of leaf guide position on output was assessed using a water phantom. The tongue and groove effect was assessed using multiple exposures on radiochromic film. Leaf reproducibility was assessed from portal images of multiple abutting fields.Results:: The maximum transmission through the multileaf collimator is 0.44% at 6 MV and 0.52% at 10 MV. This reduced to 0.22% and 0.27%, respectively, when the beam passes through the dynamic leaf guide in addition to the MLC. The maximum transmission through the thick part of the diaphragm is 0.32% and 0.36% at 6 and 10 MV. The combination of leaf and diaphragm transmission ranges from 0.08% to 0.010% at 6 MV and 0.10% to 0.14% depending on whether the shielding is through the thick or thin part of the diaphragm. The off‐axis intertip transmission for a zero leaf gap is 2.2% at 6 and 10 MV. The leaf tip penumbra for a 100 × 100 mm field ranges from 5.4 to 4.3 mm at 6 and 10 MV across the full range of leaf motion when measured in the AB direction, which reduces to 4.0–3.4 mm at 6 MV and 4.5–3.8 mm at 10 MV when measured in the GT direction. For a 50 × 50 mm field, the diaphragm penumbra ranges from 4.3 to 3.7 mm at 6 MV and 4.5 to 4.1 mm at 10 MV in the AB direction and 3.7 to 3.2 mm at 6 MV and 4.2 to 3.7 mm when measured in the GT direction. The tongue and groove effect observed from exposure of a radiochromic film to two abutting fields is an underdose of 25%. The head scatter factor at both 6 and 10 MV is similar to that from the MLCi2 collimator to within 0.8%. The uncertainty in the leaf position reproducibility is 0.05 mm (2σ).Conclusions:: The Agility collimator is a low leakage, high definition collimator where both the MLC and the sculpted diaphragm have been optimized for dynamic treatments.Keywords
This publication has 29 references indexed in Scilit:
- 1430 poster AN INNOVATIVE APPROACH TO MLC QA USING AMSI-EPID IVIEW IMAGESRadiotherapy and Oncology, 2011
- Physical Characterization of a New Concept Design of an Elekta Radiation Head with Integrated 160-leaf Multi-leaf CollimatorInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Dosimetric characteristics of the Elekta Beam Modulator™Physics in Medicine & Biology, 2005
- Intensity modulated radiation therapy with multileaf collimators of different leaf widths: a comparison of achievable dose distributionsRadiotherapy and Oncology, 2005
- Dosimetric characterization of a new miniature multileaf collimatorPhysics in Medicine & Biology, 2002
- Dynamic multileaf collimation without `tongue-and-groove' underdosage effectsPhysics in Medicine & Biology, 1996
- Multileaf collimation versus conventional shielding blocks: a time and motion study of beam shaping in radiotherapyRadiotherapy and Oncology, 1995
- The acceptability of a multileaf collimator as a replacement for conventional blocksRadiotherapy and Oncology, 1995
- The design and performance characteristics of a multileaf collimatorPhysics in Medicine & Biology, 1994
- The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantomRadiotherapy and Oncology, 1991